LA 404 Pattern Control System
40
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
Autospot Beads
With this bead type the channel output operates in dot mode when the
pattern controller is below the activation speed, and operates in normal
mode when above the activation speed. This bead type is used to relieve
residual pressure after a sudden machine stop.
6640041A
2
1
Activation Speed
Figure 10 Autospot Bead Pattern for Decelerating Line Speed
#65A=F
2T!ABA;<
$;A?
!
@01!AK!
!
%8:6K>6:!4=5=A?:?5K
4;:9E
!
/!AA
6640020A
1. To set the size of each dot (time):
a. Press the
%
or
&
button for the cursor to appear beside the numeric
value.
b. Press the
"
or
#
button to enter the desired gun-on time value from
0.1 – 50.0 ms.
2. To set the spacing between dots (pitch):
a. Press the
%
or
&
button for the cursor to appear beside the numeric
value.
b. Press the
"
or
#
button to enter the desired pitch value from
3 – 9999 mm.