Warnings
A-2
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
Engine Warnings
(contd)
Screen Message
Explanation and Action
@(99"?<2:#<(?7%'**(*
This warning appears when there is an unspecified problem with the LA404.
If the problem persists, contact your Nordson representative for assistance.
A(7#%'?2(3'*%7<B?:,
This warning appears when the encoder signal is not detected (encoder did
not move while the system was in the Run mode and at least 2 trigger
signals were received).
To correct this, confirm that the encoder is working correctly.
C':3%9'9(*>%';2''3'3
This warning appears if there are too many customized beads (stitch, dot, or
modulated) on the line. The pattern controller has a pre-determined limit that
has been exceeded.
To correct this, increase the interval or pitch (distance from the start of one
sub-bead to the start of the next sub-bead).
D3B'E#(E'3B'%';2''3'3
This warning appears if the distance limit from one edge of the bead to the
other edge of the bead has been exceeded.
To correct this, make the beads smaller, make the gaps between each bead
smaller, change the encoder gearing, or decrease the GTO.
48'*9:,%+:",#
This warning appears when the temperature in the pattern controller is
excessive.
If the problem persists, contact your Nordson representative for assistance.
@8$%78(*#%2<*2"<#
Gun Driver Overload. This fault appears when the loads on the gun driver is
drawing more than 100 watts. This may be due to too many guns
connected, improper settings, or defective loads.
@8.%78(*#%2<*2"<#
p p
g
To correct this:
"
Check spike time and hold voltage settings for the type of gun used
"
Ch k
i t
f
b i
d i
@8/%78(*#%2<*2"<#
"
Check resistance of guns being driven.
"
Electric guns should be greater than 8 ohms and pneumatic valves
should be greater than 45 ohms.
@80%78(*#%2<*2"<#
should be greater than 45 ohms.
"
Check the cable for a short.
"
The gun driver may be defective.
Engine Warning Codes
The warning codes appear as numeric codes on the menu screen. To
correct the condition default the pattern controller to the factory settings. If
the problem persists, contact your Nordson representative for assistance.