LA 404 Pattern Control System
47
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
Channel Driver Settings
Each of the four channels has a programmable voltage-mode gun driver.
The user may program the spike time duration and holding voltage for each
channel.
GE=<!H!1!)5;I?5!+?:8>
+>;D?!$;A?!!!!!!!!!10W!AK!
!
V6F7!.6F:=J?!!!!!!!T!.
6640025A
1. To select Chan (Channel) number’s 1 – 4, press the CHANNEL SELECT
button on the front panel of the patten controller.
2. To set spike time:
a. Press the
%
or
&
button for the cursor to appear beside the numeric
value.
b. Press the
"
or
#
button to set the desired value from 0.0 – 5.0 ms.
3. To set hold voltage:
a. Press the
%
or
&
button for the cursor to appear beside the numeric
value.
b. Press the
"
or
#
button to set to 5 V, 10 V, or 24 V.
NOTE:
When a holding voltage of 5 V is selected, the over-energize
range time is 0.1 – 5 ms. When a holding voltage of 10 V is selected,the
over-energize range time is 0.1 – 15 ms. When a holding voltage of
24 V is selected, the over-energize range time is 0.1 – 15 ms.
Guns Supported By Pattern Controller Driver Boards
Electric guns:
$
LA 820, recommended settings:
Spike Time: 1.8 ms/Hold Voltage: 5 V
$
LA 844, recommended settings:
Spike Time: 2 ms/Hold Voltage: 5 V
$
LA 822, recommended settings:
Spike Time: 2.5 ms/Hold Voltage: 10 V
The pattern controller supports 24 VDC pneumatic guns,
recommended settings: Spike Time: 0 ms/Hold Voltage: 24 V