LA 404 Pattern Control System
51
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
Purge Pressure
The setup menu is used to configure the run-up pressures when purge is
activated. In addition the user may configure the operational mode of the
purge button on the front panel. When set to purge, the gun outputs are
maintained as long as the button is activated. When set to flush,
depressing the button activates the gun channel output, and pressing the
button again deactivates the gun channel output. This feature is used for
flushing liquid adhesive system.
485J?!45?KK85?
,8<!]>!1!!!!!!!!!!!!!!1@N!
!
485J?!*67?!!!!!!!!!!!!485J?
,8<!]>!2!!!!!!!!!!!!!!1@N
6640029A
1. To set run up 1:
a. Press the
%
or
&
button for the cursor to appear beside the
percentage value.
b. Press the
"
or
#
button to set to the desired the value from
0 – 100%.
2. To set run up 2:
a. Press the
%
or
&
button for the cursor to appear beside the
percentage value.
b. Press the
"
or
#
button to set to the desired the value from
0 – 100%.
3. To set purge mode:
a. Press the
%
or
&
button for the cursor to appear beside Purge.
b. Press the
"
or
#
button to set to Flush or Purge.
Remote Purge
Each channel output has an individual remote purge input, and a switch
closure on the remote purge input activates the channel output.