LA 404 Pattern Control System
53
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
System Settings 2
This setup menu is used to configure automatic and manual startup of the
pattern controller, the trigger memory function, and to enable and disable
the remote recall of programs.
When the autostart feature is on the pattern controller will automatically be
placed in run mode when the unit is powered. When set to off, the pattern
controller will
always
be placed in STANDBY when the unit is powered.
The trigger memory function allows the user to either apply or not apply
adhesive to products between the trigger and the guns when line speed
recovers after falling below the stop speed setting. When set to off, the
pattern is terminated, and when set to on the pattern resumes when the line
speed is above the start speed setting.
The remote recall feature allows the programs to be selected either from the
front panel or remotely from the remote input jack. When set to off, 50
programs can be selected from the front panel. When on, 32 programs can
be selected through the remote input jack.
+SK:?A!+?::;<JK!2
%8:6K:=5:!!!!!!!!!!!!!-<
$5;J!*?A65S!!!!!!!!!!!-MM!
!
,?A6:?!,?9=FF!!!!!!!!!-MM
6640031A
1. To set autostart:
a. Press the
%
or
&
button for the cursor to appear beside On/Off.
b. Press the
"
or
#
button to select On or Off.
NOTE:
The Autostart feature controls the enabling and disabling of
pattern generation on power-up. If set to OFF, then all the channels are
set to STANDBY on power-up. If set to ON, then all the channels that
were in RUN when powered down will RUN when powered up. The
default setting is Autostart OFF.
2. To set trigger memory:
a. Press the
%
or
&
button for the cursor to appear beside On/Off.
b. Press the
"
or
#
button to select On or Off.
Содержание LA 404
Страница 28: ......