LA 404 Pattern Control System
21
Part 1037527
B
!
200
5
Nordson Corporation
Manual 66-LA404-MA-01
Remote Input Plug
The remote input plug provided in the ship-with kit connects to the
Remote
Input
connector, it is typically used to prevent the pattern controller from
dispensing adhesive until a melter or parent machine is
ready
as shown in
Figure 5.
To enable the pattern controller to begin dispensing adhesive:
Connect the 24 VDC (
Remote Input
plug, pin 1) to the enable input
(
Remote Input
plug, pin 7) using an electrically isolated contact. Refer
to the
Remote Input
pin drawing under
I/O Connector Pin Layout
.
To bypass (or to set to INACTIVE) the remote enable function, refer to
System Settings 3
.
6640036A
Melter
LA404 Pattern Controller
1
7
Remote Input
Connectors
Ready Contact
Figure 5
Connecting the Pattern Controller to the Melter for Pattern Generation
Содержание LA 404