32
Chapter 4
Communications Specification
4
3-7-4.
Switching to Remote by Equipment (Operator)
The operator switches equipment control mode from local to remote.
<Scenario>
○
Remote selected by operator
Message: S6F11,F12
<Comment>
[Host]
[Equipment] <Comment>
←
S6F11
Transmits event report; control state is remote.
Acknowledges
S6F12
→
3-7-5.
Switching to Local by Equipment (Operator)
The operator switches equipment control mode from remote to local.
<Scenario>
○
Local selected by operator
Message: S6F11,F12
<Comment>
[Host]
[Equipment] <Comment>
←
S6F11
Transmits event report; control state is local.
Acknowledges
S6F12
→
3-7-6.
Switching to Offline by Host
<Scenario>
○
Offline selected by host
Message: S1F0,F15,F16,S6F11,F12
<Comment>
[Host]
[Equipment] <Comment>
Request to switch to offline mode.
S1F15
→
[IF]
The equipment is offline;
[THEN]
←
S1F10
Rejects request.
[ELSE]
←
S1F16
Accepts request.
←
S6F11
Transmits event report; host offline.
Acknowledges
S6F12
→
[END_IF]
3-7-7.
Switching to Online by Host
<Scenario>
○
Online selected by host
Message: S1F17,F18,S6F11,F12
<Comment>
[Host]
[Equipment] <Comment>
Request to switch to online mode.
S1F17
→
[IF]
Other than host offline;
[THEN]
←
S1F18
Rejects request. (other than ONLACK0)
[ELSE]
←
S1F18
Accepts request. (ONLACK = 0)
←
S6F11
Transmits event report; control state is local
(remote).
Acknowledges
S6F12
→
[END_IF]