34
Chapter 4
Communications Specification
4
3-10. Status Data Collection
The host can query the equipment for status information selected by the host.
<Scenario>
○
Equipment status report request
Message: S1F3,F4
<Comment>
[Host]
[Equipment] <Comment>
Requests status variable report.
S1F3
→
←
S1F4
Replies by transmitting requested status variable
data.
○
Equipment status variable name list request
Message: S1F11,F12
<Comment>
[Host]
[Equipment] <Comment>
Requests acknowledgement of selected
S1F11
→
status variable.
←
S1F12
Replies by transmitting description of requested
status variable.
3-11. Error Message
The equipment notifies the host of messages and errors in communications detected by the equipment.
3-11-1. Message Error by Unrecognized Device ID
<Scenario>
○
Message error by unrecognized device ID
Message: S9F1
<Comment>
[Host]
[Equipment] <Comment>
Transmits a message.
SxFx
→
Detects unrecognized device ID.
←
S9F1
Notifies the host that an unrecognized device ID
is detected.
3-11-2. Message Error by Unrecognized Stream Type
<Scenario>
○
Message error by unrecognized stream type
Message: S9F3
<Comment>
[Host]
[Equipment] <Comment>
Transmits a message.
SxFx
→
Detects unrecognized stream type.
←
S9F3
Notifies the host that an unrecognized stream
type is detected.
3-11-3. Message Error by Unrecognized Function Type
<Scenario>
○
Message error by unrecognized function type
Message: S9F5
<Comment>
[Host]
[Equipment] <Comment>
Transmits a message.
SxFx
→
Detects unrecognized function type.
←
S9F5
Notifies the host that an unrecognized function
type is detected.