76
Chapter 4
Communications Specification
4
Message
Variable
S2F39
S6F5
DATALENGHTH
Total length (byte count) of the message data
Format: 30, 31
(32 or 34 for the
sign, 50 or 51 for
Yes/No, 52 or 54 for
integer)
Constant
Format
5-16. DATALENGHTH
Message
Variable
S2F33
S2F35
S2F39
S6F5
S6F11
DATAID
Data ID = 0
Used to identify a series of data collectively. It is
used particularly for a series of data having a high
likelihood of multi-block transmission. (This is
used for a multi-block data format send inquiry.)
It is set to 0.
Format: 51
(1-byte integer)
Constant
Format
5-17. DATAID
Message
Variable
S2F34
DRACK
Define report acknowledge code
0 = Accepted
1 = Denied, insufficient space
2 = Denied, incorrect format
3 = Denied. At least one RPTID is already defined.
4 = Denied. At least one VID does not exist.
>4 = Other errors
Format:10
(Binary)
Constant
Format
5-18. DRACK
Message
Variable
S2F16
EAC
Equipment acknowledge code. Reply to host
request to modify equipment constants. 1 byte
0 = Accepted
1 = Denied. No constant exists.
2 = Denied. Busy
3 = Denied. The constant falls outside the range.
4 = Denied. Unrecognized command
>4 = Other errors
Format:10
(Binary)
Constant
Format
5-19. EAC
Содержание NWL860 Series
Страница 1: ...M232 E 04 7 CF 3 Wafer Loader NWL860 Series IFC Function SECS Communications Specifications ...
Страница 3: ......
Страница 22: ......
Страница 96: ......