24
Chapter 4
Communications Specification
4
State
INIT
IDLE
ACTIVE
PAUSE
ERROR
MAINTENANCE
SET-UP
The equipment is undergoing system initialization.
The equipment is ON and awaiting commands.
The equipment is ON and operating.
The equipment is temporarily halted.
The equipment is in an error state.
The equipment is in maintenance status.
The equipment is in setup status.
Explanation
■
State Transition Event
See “5-11. CEID” in this chapter.
■
Variables of Current and Preceding Processing States
Event reports for current and the preceding processing states (S6F11,F12) and inquiries for processing
state (S1F3,F4) may be available, through the particular communications software.
1-4.
Saving of Settings
The following status settings are stored in non-volatile memory.
GEM-Defined
Capabilities
Establishment of
Communications
Control
Event Report
Alarm
Management
Time (seconds) within which
S1F13 must be transmitted
once communications are
established.
Online/Offline
Equipment Online/
Online Establishment Try/
Host Offline
Enable or disable event
transmission.
ID attached to the report, and
VID representing the
attributive value of the report
Report ID linked to the
collection event.
Enable or disable alarm
transmission.
Comment
Equipment Parameter
Establish communications
time-out (constant)
Control state at equipment
startup (constant)
The offline sub-state at
equipment startup (constant)
Setting parameter for event
enable/disable S2F37
Setting parameter for define
report S2F33: Report ID,
variable ID
Setting parameter for link
event report S2F35: Event ID,
report ID
Alarm enable/disable
Related Data
Estabilish
Communication
Timeout
Control State (variable)
Control State (variable)
Event Enabled reflects
the CEID of the enabled
event.
RPTID,VID
CEID,VID
Alarms Enabled reflects
the ALID of the enabled
alarm.
Содержание NWL860 Series
Страница 1: ...M232 E 04 7 CF 3 Wafer Loader NWL860 Series IFC Function SECS Communications Specifications ...
Страница 3: ......
Страница 22: ......
Страница 96: ......