31
Chapter 4
Communications Specification
4
3-6-4.
Report Transmission upon Request
The equipment transmits the report requested by the host to the host.
The equipment does not send a multi-block data send inquiry before transmission, even if the
report is to be transmitted in multi-block data format.
<Scenario>
○
Report request by host
Message: S6F19,F20
<Comment>
[Host]
[Equipment] <Comment>
Requests variable data in RPTID.
S6F19
→
←
S6F20
Transmits the variable data for the given RPTID.
3-7.
Control Mode Selection
Switches from one control mode to another (Offline/Online Local/Online Remote).
3-7-1.
Switching to Online by Equipment (Operator) — (Permitted by Host)
The operator switches equipment control mode from offline to online.
<Scenario>
○
Online permitted by host
Message: S1F1,F2,S6F11,F12
<Comment>
[Host]
[Equipment] <Comment>
←
S1F1
Request to switch to online mode.
Grants request to switch to online mode.
S1F2
→
←
S6F11
Transmits event report; control state is local
(remote).
Acknowledges
S6F12
→
3-7-2.
Switching to Online by Equipment (Operator) — (Rejected by Host)
<Scenario>
○
Online rejected by host
Message: S1F1,F0
<Comment>
[Host]
[Equipment] <Comment>
←
S1F1
Request to switch to online mode.
Rejects request to switch to online mode.
S1F0
→
3-7-3.
Switching to Offline by Equipment (Operator)
The operator switches equipment control mode from online to offline.
<Scenario>
○
Offline selected by operator
Message: S6F11,F12
<Comment>
[Host]
[Equipment] <Comment>
←
S6F11
Transmits event report; equipment offline.
Acknowledges
S6F12
→