5.4 Command List
5-17
ZM2371/ZM2372
Table 5
–3 Subsystem command list (2/3)
Command
Function / Operation target
CALCulate3 subsystem
:CALCulate3:MATH:STATe
Enables IV monitor display
CALCulate4 subsystem
:CALCulate4:MATH:STATe
Enables IV monitor display
CALibration subsystem
:CALibration:CABLe
Cable length correction
DATA subsystem
:DATA[:DATA]
Reference value for primary & secondary
parameter deviation display
:DATA[:DATA]?
Queries reference value for deviation
display, contents of data buffer, and IV
monitored value
:DATA:FEED
Recorded data in measured data buffer
:DATA:FEED:CONTrol
Enables recording in measured data
buffer
:DATA:POINts
Measured data buffer virtual size and
initialization
DISPlay subsystem
:DISPlay[:WINDow][:STATe]
Enables measured value display (enabled
at all times)
:DISPlay[:WINDow]:TEXT1:DIGit
Number of measured value display digits
(fixed)
:DISPlay[:WINDow]:TEXT1:PAGE
Measured value/Comparator result
selection (both at all times)
:DISPlay[:WINDow]:TEXT2:PAGE
Auxiliary display item (function limited)
:DISPlay[:WINDow]:TEXT3[:PAGE]
Auxiliary display item
FETCh subsystem
:FETCh?
Query of latest measured data
FORMat subsystem
:FORMat[:DATA]
Measured data transfer format
INITiate subsystem
:INITiate:CONTinuous
Continuous starting of trigger system
:INITiate[:IMMediate]
Starting of trigger system
READ subsystem
:READ?
Trigger, and data query after
measurement
SENSe subsystem
[:SENSe]:AVERage:COUNt
Averaging count
[:SENSe]:AVERage[:STATe]
Enables the averaging
[:SENSe]:CORRection:CKIT:STANdard1:FORMat
Format of OPEN correction value
[:SENSe]:CORRection:CKIT:STANdard2:FORMat
Format of SHORT correction value
[:SENSe]:CORRection:CKIT:STANdard3
Standard value for LOAD correction
[:SENSe]:CORRection:CKIT:STANdard3:FORMat
Format of LOAD correction value /
standard value
[:SENSe]:CORRection:COLLect[:ACQuire]
Measurement of correction value
[:SENSe]:CORRection:COLLect:METHod
Correction operating target
[:SENSe]:CORRection:DATA
Correction value
[:SENSe]:CORRection:LIMit:LOW
Correction lower limit frequency
[:SENSe]:CORRection:LOAD[:STATe]
Enables LOAD correction
[:SENSe]:CORRection:OPEN[:STATe]
Enables OPEN correction
[:SENSe]:CORRection:SHORT[:STATe]
Enables SHORT correction
[:SENSe]:CORRection:SPOT[:STATe]
Enables SPOT correction measurement
[:SENSe]:CORRection[:STATe]
Enables correction in a
lump
Содержание ZM2371
Страница 1: ...NF Corporation LCR METER ZM2371 ZM2372 Instruction Manual...
Страница 2: ......
Страница 3: ...LCR METER ZM2371 ZM2372 Instruction Manual DA00026021 007...
Страница 250: ......
Страница 252: ......
Страница 253: ......
Страница 254: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...
Страница 255: ...BLANK...