5.2 Command Lists
FRA5014
5-7
5.2 Command Lists
The
FRA5014
’s commands are broadly divided into common commands defined by IEEE488.2 and
subsystem commands that support device-specific functions.
Table 5-1 lists the
FRA5014
’s subsystem commands. The common commands supported by the
FRA5014
are listed in Table 5-2. The symbols used in Table 5-1 and Table 5-2 are explained
below. The parts of key words shown in lowercase letters can be omitted.
•
A query command ends with a question mark (?). In the command lists, “query” is omitted
in cases where both a setting and a query are enabled.
•
Square brackets ([ ]) indicate key words that can be omitted (implicit key words) .
•
A vertical bar ( | ) indicates when one of several key words is selected.
Table 5-1. FRA5014 Subsystem Command List
Function
Command
CALibration subsystem
Self calibration
:CALibration[:ALL]?
INPut subsystem
Overload input detection level
:INPut(1|2|3|4):VOLTage:OVERload[:LEVel]
Processing during overload input
:INPut:VOLTage:OVERload:RESPonse
Input weighting
:INPut:GAIN
MEASure subsystem
Measurement delay time
:MEASure:DELay[:TIME]
Integration cycle
:MEASure:INTegrate:CYCle
Integration time
:MEASure:INTegrate:TIME
SENSE subsystem
Read sweep measurement data
:SENSe:DATA:SWEep[:DATA][:ALL]?
Select and read sweep measurement data
:SENSe:DATA:SWEep[:DATA]:SELected?
Read sweep measurement points
:SENSe:DATA:SWEep:POINt?
Read spot measurement data
:SENSe:DATA:SPOT[:DATA][:ALL]?
Read spot measurement data in complex
format
:SENSe:DATA:SPOT[:DATA]:COMPlex?
Select and read spot measurement data
:SENSe:DATA:SPOT[:DATA]:SELected?
Spot gain judgment upper limit
:SENSe:DATA:SPOT:LIMit:GAIN:MAXimum
Spot gain judgment lower limit
:SENSe:DATA:SPOT:LIMit:GAIN:MINimum
Spot phase judgment upper limit
:SENSe:DATA:SPOT:LIMit:PHASe:MAXimum
Spot phase judgment lower limit
:SENSe:DATA:SPOT:LIMit:PHASe:MINimum
Read spot judgment results
:SENSe:DATA:SPOT:LIMit:REPort[:ALL]?
Select and read spot judgment results
:SENSe:DATA:SPOT:LIMit:REPort:SELected?
SOURce subsystem
Oscillator frequency
[:SOURce]:FREQuency[:IMMediate]
Measurement operations
[:SOURce]:SWEep:MEASure
Sweep frequency axis format
[:SOURce]:SWEep:SPACing[:TYPE]
Sweep frequency points
[:SOURce]:SWEep:SPACing:POINt
Sweep upper limit frequency
[:SOURce]:SWEep[:LEVel]:MAXimum
Sweep lower limit frequency
[:SOURce]:SWEep[:LEVel]:MINimum
Oscillation frequency
[:SOURce]:VOLTage:OUTPut[:STATe]
Measurement operations
[:SOURce]:VOLTage:OFFSet[:IMMediate]
Oscillator AC amplitude
[:SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
AC amplitude unit
[:SOURce]:VOLTage:UNIT
(1/2)
Содержание FRA5014
Страница 1: ...NF Corporation SERVO ANALYZER FRA5014 Instruction Manual...
Страница 2: ......
Страница 3: ...SERVO ANALYZER FRA5014 Instruction Manual DA00019832 004...
Страница 10: ...Contents FRA5014 vi 8 7 General Items 8 6...
Страница 26: ...2 2 Installation FRA5014 2 8 Figure 2 5 Removal of Feet...
Страница 30: ......
Страница 48: ......
Страница 96: ......
Страница 107: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima higashi Kohoku ku Yokohama 223 8508 JAPAN...