- 26 -
www.New-Leader.com
(800) 363-1771
314520-AA-A
Page Rev. A
NEW LEADER • NL5000G5 AGCO
Header
HYDRAULIC HOSE INSTALLATION
CAUTION
If a threaded connection is tightened too tightly, the fitting or housing into which the
fitting is placed could be distorted and an unstoppable leak could occur.
WARNING
Do not use one manufacturer’s hose with another manufacturer’s fittings! Such will void
any warranty and may cause premature burst or leak of hydraulic fluids! Severe injury
and/or fire could result!
Locate zero pressure case drain port on chassis. Connect this hose to chassis first. Next connect return hose to
return port. Connect pressure hose to pressure port last. Use plastic tie straps as necessary to support hoses so
they will not catch on field obstructions or contact hot or moving parts.
Header
Installation
INSTALLING BODY
NOTICE!
DO NOT WELD ON VEHICLE FRAME! Such welding can lead to fatigue cracking and must be
avoided.
NOTICE!
Connect welders ground directly to one of the items being welded anytime an arc welder is used
on the vehicle or anything connected to the vehicle. Refer to Manufacturer’s instructions.
IMPORTANT!
Disconnect electrical components from electrical system when welding on equipment to
prevent component damage due to power surges or excessive current.
Mounts
CAUTION
Refer to chassis operator’s manual for specific procedures on tightening mounting
hardware. Failure to follow procedure per chassis manufacturer may result in injury or
machine damage.
Position unit over chassis and align mounts. Carefully lower unit onto chassis.Install mounting hardware and
tighten to specified torque. Refer to chassis operator’s manual for specific hardware tightening procedures.