Enter appropriate settings:
•
Valve Response 1 - Determines speed of servo valve when product control error exceeds Response
Threshold setting. Represents fast speed of servo valve. Decreasing value will cause servo valve to run
slower. Default setting is 40%.
•
Valve Response 2 - Determines speed of servo valve when product control error is less than Response
Threshold setting. Represents slow speed of servo valve. Decreasing value causes servo valve to run
slower. Default setting is 8%.
•
Response Threshold - Determines where control channel switches between using Valve Response 1 and
Valve Response 2 speed setting. Leaving all other valve control settings at default value and making
small adjustments to this settting is usually all that is required to fine-tune system performance. Default
setting is 4.
NOTE:
•
Decreasing Response Threshold value will have overall effect of speeding up servo valve
response.
•
Increasing Response Threshold value will have overall effect of slowing servo valve response.
•
Allowable Error - Determines the percent of error that is allowed prior to product control system making
any flow rate changes. 2% - 3% is nzormal dead band setting range.
ALARM SETTINGS
•