Alarms
FEED GATE ALARMS
Alarm
Description
Trigger
Feed Gate Not
Calibrated
“Feed Gate must be calibrated prior to
operation.” + [Bin Name]
[Feed Gate Enable/Disable] is Enabled,
equipment profile is active and feed gate
actuator has not been calibrated.
Feed Gate
Movement
“Feed Gate may move at this time. Please
keep clear of feed gate.” + [Bin Name]
Upon user acknowledgement, dialog is
dismissed and warning flashes on interval in
the status bar until corresponding feed gate
calibration is complete.
Feed Gate
Movement During
Calibration
“Feed gate will move during calibration.
Please wait.”
Upon user acknowledgement, system moves
feed gate.
Feed Gate Not
Responding
“Feed Gate not responding.” + [Bin Name]
Upon user acknowledgement, dialog is
dismissed. System allows product application
at current feed gate position.
Feed Gate Sensor
Outside Expected
Operating Range
“Feed Gate sensor outside expected
operating range. Check sensor, and related
wiring.” + [Bin Name]
Upon user acknowledgement, dialog is
dismissed. System allows product application
at current feed gate position, and feed gate
control is disabled.
Feed Gate Position
Sensor Error
During Calibration
Routine
“Lost or intermittent signal from feed gate
position sensor. Check sensor and related
wiring prior to continuing calibration
routine.”
Upon user acknowledgement, calibration
routine is exited.
No Feedback from
Position Sensor
“No Feedback from Position Sensor.” + [Bin
Name]
Upon user acknowledgement, dialog is
dismissed. System allows product application
at current position.
Feed Gate out of
Position (Position
Sensor Reporting
Wrong Position)
“Feed Gate Out of Position.”
Upon user acknowledgement, dialog is
dismissed. System allows product application
at current position.
Feed Gate Circuit
Disabled
“Feed Gate Circuit Disabled.”
“Pressing acknowledge will enable and
allow feed gate to move. Do you wish to
proceed?”
Upon user acknowledgement, dialog is
dismissed. System sets feed gate circuit to
“Enabled”, Feed Gate movement dialog is
presented and system moves feed gate to user
defined Feed Gate Height setting.