- 131 -
NEW LEADER • NL5000G5 AGCO
www.New-Leader.com
(800) 363-1771
314520-AA-A
Page Rev. A
Header
Alarms
GENERAL PRODUCT CONTROL ALARMS
Alarm
Description
Trigger
Rate sensor error
during calibration
“Calibration error, lost or intermittent signal
from rate sensor. Check sensor and related
wiring prior to calibrating conveyor.”
Rate sensor signal is lost for a period of
two or more consecutive seconds during
the Static Conveyor Calibration Routine.
Rate Sensor Error
During Conveyor
Flush
"Lost or intermittent signal from rate sensor.
Check sensor and related wiring prior to
continuing Conveyor Flush Routine."
Rate sensor signal is lost for a period of
two or more consecutive seconds during
the Conveyor Flush Routine.
Low Bin Sensor
"Low Bin Sensor." + channel name.
Bin Level Sensor is installed, metering
circuit is commanded on, and the product
in the bin does not cover the sensor for a
consecutive period of time greater than
current [Low Bin Time Delay] setting.
Disable Spinners
"Manually disable or shut off the spinner
hydraulic circuit."
At the beginning of the Static Conveyor
Calibration and Conveyor flush routine.
Enable Spinners
"Return the spinner hydraulic control to a
field ready condition. The spinners will now
restart."
At the end of the Static Conveyor
Calibration routine and Conveyor flush
routine.
Boundary Spinner
Not Responding
"Boundary Spinner Not Responding." +
[Spinner Name]
Automatic control for spinners must be
enabled. At least one conveyor must be
commanded on. Perceived spinner speed
is greater than 30RPM in error from the
[Boundary Spreading Spinner RPM Offset].
Rate Not
Responding
“Rate Not Responding” + Channel Name
Control channel is commanded on using
automatic control mode. Application rate
is +/- [Rate Not Responding Threshold]
from target rate for a period of [Rate Not
Responding Timeout] or more.
Rate Not
Responding
“Rate Not Responding.” + Channel Name.
Control channel is commanded on using
automatic control mode. Application rate
is +/- [Rate Not Responding Threshold]
from target rate for a period of [Rate Not
Responding Timeout] or more.
Maximum
Conveyor Speed
Conveyor At Maximum RPM, Slow Down +
Channel Name.
Product channel is commanded on and
conveyor is run at or above maximum
speed for a period of 5 or more
consecutive seconds.
Minimum
Conveyor Speed
Conveyor At Maximum RPM, Slow Down +
Channel Name.
Product channel is commanded on and
conveyor is run at or below minimum
speed for a period of 5 or more
consecutive seconds.
Conveyor Not
Responding
Conveyor Running While Turned Off + Channel
Name.
Product bin is commanded off and
conveyor speed >0 and <1 RPM for a
period of 30 or more consecutive seconds.
Or conveyor speed is >=1 RPM for a period