- 135 -
NEW LEADER • NL5000G5 AGCO
www.New-Leader.com
(800) 363-1771
314520-AA-A
Page Rev. A
Header
Alarms
HYDRAULIC ALARMS
Alarm
Description
Trigger
Conveyor Hydraulic
Pressure Exceeds
Maximum
“Conveyor Hydraulic Pressure Exceeds
Maximum Operating Range.”
Conveyor hydraulic pressure exceeds [Max
Conveyor Hydraulics Pressure] setting for a
period of five consecutive seconds or longer.
System Hydraulic
Pressure Exceeds
Maximum
“System Hydraulic Pressure Exceeds
Maximum Operating Range.”
System hydraulic pressure exceeds [Max
System Hydraulics Pressure] setting for a
period of five consecutive seconds or longer.
Hydraulic Fluid
Level Low
“Hydraulic Fluid Level Low.”
Hydraulic fluid level has fallen below lowest
level tank sensor.
Hydraulic Fluid
Temperature
Below Minimum
“Hydraulic Fluid Temperature Below
Minimum Operating Range.”
Hydraulic temperature is below 65°F (18°C).
Hydraulic fluid too cold to operate machine.
Hydraulic Fluid
Temperature
Exceeds Maximum
“Hydraulic Fluid Temperature Exceeds
Maximum Operating Range.”
Hydraulic temperature exceeds maximum
operating range, greater than or equal to
200°F (93°C).
Hydraulic Filter
Restriction
Detected
“Hydraulic Filter Restriction Detected.”
Hydraulic filter pressure is greater than or
equal to 25 psi for five consecutive seconds or
longer.
BIN SEQUENCING ALARMS
Alarm
Description
Trigger
Container Advance Moving to next container in the sequence. At the point when the [Container Advance]
criteria has been met.
End of Sequence
End of container sequence, do you wish to
start the sequence from the beginning?
At the point the last container in the sequence
has met the [Container Advance] criteria.
CHAIN OILER ALARMS
Alarm
Description
Trigger
Disable Spinners
Manually disable or shut off the spinner
hydraulic circuit.
The point the user selects to run the chain
oiler routine.
Enable Spinners
Return the spinner hydraulic circuit to a field
ready condition.
The point the user exits the chain oiler
routine.
Conveyor
Lubrication
Required
Conveyor Chain Lubrication Is Required.
[Service Reminder On] setting is enabled and
[Service Reminder Interval] has expired.