BIOS Setup Utility
77
CPU C6 Report
[Disabled]
[Enabled]
Enable/Disable CPU
C6(ACPI C3) report to
OS.
Only appears when
Power Technology is
set to [Custom].
CPU C7 Report
[Disabled]
[Enabled]
Enable/Disable CPU
C7(ACPI C3) report to
OS.
Only appears when
Power Technology is
set to [Custom].
Energy Performance
[Performance]
[Bal-
anced Performance]
[Balanced Energy] [En-
ergy Efficient]
Optimize between per-
formance and pow-
er savings. Windows
2008 and later Oses
overrides this value ac-
cording to its power
plan.
PL1 Clamp Bit
[Disabled]
[Enabled]
When enabled, allows
processor to go below
the OS requested P
States in order to main-
tain the power below
Long Duration Power
Limit. NOTE: Intel rec-
ommends not to en-
able it.
PL2 Clamp Bit
[Disabled]
[Enabled]
When enabled, allows
processor to go below
the OS requested P
States in order to main-
tain the power below
Short Duration Pow-
er Limit. NOTE: BIOS
must not enable it.
Factory long duration
power limit
Information only. Dis-
plays the Factory long
duration power limit.
Long duration power
limit
Long duration power
limit in Watts.
Factory long duration
maintained
Information only. Dis-
plays the Factory long
duration maintained.
Long duration main-
tained
Time window which the
long duration power is
maintained.
Recommended short
duration power
Information only. Dis-
plays the Recommend-
ed short duration pow-
er.
Short duration power
limit
Short duration power
limit in Watts.
Содержание Demos R130 M2
Страница 1: ...Netberg Demos R130 M2 server...
Страница 2: ...Netberg Demos R130 M2 server...
Страница 11: ...Netberg Demos R130 M2 server xi 9 5 Aligning the Rails 222...
Страница 14: ...1 Chapter 1 Netberg Demos R130 M2 server...
Страница 31: ...Netberg Demos R130 M2 server 18 On HDD failure HDD Fault Amber Off No failure detected...
Страница 32: ...19 Chapter 2 Installing hardware...
Страница 57: ...Installing hardware 44 Figure 2 36 Installing the Air Duct...
Страница 60: ...Installing hardware 47 Figure 2 40 Connecting the Fan Assembly Cables...
Страница 143: ...130 Chapter 6 Server Management Software...
Страница 146: ...Server Management Software 133 6 3 Power System BMC controls system power through GPIO pins and IPMI chassis commands...
Страница 166: ...153 Chapter 7 BMC Recovery This section provides guidelines on BMC recovery process in DOS and Linux systems...
Страница 169: ...156 Chapter 8 Web Graphical User Interface GUI for ESMS...
Страница 230: ...217 Chapter 9 Rail Kit Assembly...
Страница 233: ...Rail Kit Assembly 220 Figure 9 3 Securing the Inner Rail 5 Repeat steps 1 through 3 for the remaining side...
Страница 236: ...223 Chapter 10 Troubleshooting...