Netberg Demos R130 M2 server
9
Processor (2x)
Intel® Xeon® E5-2600 v3 series processors (135W with max configuration,
145W with limitations)
Chipset
Intel® C610 (Wellsburg)
PCI-E
(1) PCIe x16 v3 Low Profile MD-2
(1) PCIe x8 v3 OCP Mezzanine slot
(1) PCIe x8 v3 SAS/RAID Mezzanine slot
Memory
(24) DDR4 1333/1600/1866/2133 MHz ECC UDIMM/RDIMM/LRDIMM slots
up to 768 GB
Storage Controller Onboard (Intel® C610):
* 10 x SATA 6 Gb/s ports
* SATA RAID 0, 1, 10
Optional controller:
* LSI 2308 6G/s SAS mezzanine card, RAID0, 1, 10
* LSI 3008 12G/s SAS mezzanine card, RAID0, 1, 10
* LSI 2108 6 GB/s RAID mezzanine card, RAID0, 1, 5, 10, RAID6 with addi-
tional RAID key
* LSI 2208 6 GB/s RAID mezzanine card, RAID0, 1, 5, 10, RAID6 with addi-
tional RAID key
Storage
(10) 2.5" SATA/SAS hot-plug HDD/SSD drives including (2) 2.5 NVMe PCIe
SSD or (4) 3.5" SATA/SAS hot-plug drives,
(2) SATADOM (optional)
Networking
LOM:
(2) Intel® Powerville I350 GbE RJ45 ports or
(2) Intel® Twinville X540 10G BASE-T RJ45 ports
(1) dedicated 1GbE RJ45 management port
Optional NIC:
(2) Intel® Powerville I350 GbE ports OCP mezzanine cards
(2) Intel® Twinville X540 10G BASE-T ports OCP mezzanine cards
(2) Intel® 82599ES 10G SFP+ ports OCP mezzanine cards
Video
Aspeed AST2400 8 MB DDR3 Video memory
Front I/O
Power/ID/Reset Buttons
LAN/HDD/Status/ID LEDs
Содержание Demos R130 M2
Страница 1: ...Netberg Demos R130 M2 server...
Страница 2: ...Netberg Demos R130 M2 server...
Страница 11: ...Netberg Demos R130 M2 server xi 9 5 Aligning the Rails 222...
Страница 14: ...1 Chapter 1 Netberg Demos R130 M2 server...
Страница 31: ...Netberg Demos R130 M2 server 18 On HDD failure HDD Fault Amber Off No failure detected...
Страница 32: ...19 Chapter 2 Installing hardware...
Страница 57: ...Installing hardware 44 Figure 2 36 Installing the Air Duct...
Страница 60: ...Installing hardware 47 Figure 2 40 Connecting the Fan Assembly Cables...
Страница 143: ...130 Chapter 6 Server Management Software...
Страница 146: ...Server Management Software 133 6 3 Power System BMC controls system power through GPIO pins and IPMI chassis commands...
Страница 166: ...153 Chapter 7 BMC Recovery This section provides guidelines on BMC recovery process in DOS and Linux systems...
Страница 169: ...156 Chapter 8 Web Graphical User Interface GUI for ESMS...
Страница 230: ...217 Chapter 9 Rail Kit Assembly...
Страница 233: ...Rail Kit Assembly 220 Figure 9 3 Securing the Inner Rail 5 Repeat steps 1 through 3 for the remaining side...
Страница 236: ...223 Chapter 10 Troubleshooting...