6.8. SEL
BMC supports IPMI 1.5/2.0 standard SEL operation. It can keep SEL log. Event happened in
BIOS side will be logged by using Add SEL Entry command. BMC will store them in FLASH, the
time stamp field will be filled by BMC. When SEL is full, the new SEL won’t be logged but will go
through PEF as usual. If AC powers off, all SELs will remain in NV.