902
Program
Number
Program Name/Description
Input Data
Default
22-02-01
Incoming Call Trunk Setup
Set the feature type for the trunk you are
programming. For each Night Service mode,
enter 5 when the trunk should be an E&M tie
line.
0 = Normal
1 = VRS (second dial tone if no
VRS installed)
2 = DISA
3 = DID
4 = DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode Switching
0
34-01-01
E&M Tie Line Basic Setup
– DID/E&M Start
Signaling
Set the start signaling mode for DID and Tie
trunks. They can use either immediate start or
Wink start signaling.
0 = 2nd Dial Tone
1 = Wink (default)
2 = Immediate
3 = Delay
1
34-01-03
E&M Tie Line Basic Setup
– E&M Dial-In
Mode
Determine if the incoming Tie Line call should
be directed as an intercom call or if it should
follow the DID Translation Table in Program
22-11-01.
0 = Specify Extension Number
(Intercom)
1 = Use Conversion Table (NTT)
0
34-01-04
E&M Tie Line Basic Setup
– E&M Line Dial
Tone
Enable if the Tie Line should send dial tone to
the calling system after the call is set up.
Disable if the Tie Line should not send dial tone.
0 = Disable (No)
1 = Enable (Yes)
1
34-01-05
E&M Tie Line Basic Setup
– System Toll
Restriction
Determine if an incoming Tie Line call should
be subject to Toll Restriction.
0 = No (Off)
1 = Yes (On)
0
34-02-01
E&M Tie Line Class of Service
Assign the Tie Line Class of Service (1 ~ 15).
Use Program 20-14-01 to set the Tie Line Class
of Service options. You cannot use Program
20-06 to assign Class of Service to Tie Lines.
Day/Night Mode
1 ~ 8
Class: 1 ~ 15
1
34-03-01
Trunk Group Routing for E&M Tie Lines
Assign the trunk group route chosen when a
user seizes a Tie Line and dials 9. Set Trunk
Group Routing in Program 14-06-01. If the
system has ARS, dial 9 to access ARS.
0 ~ 100
(0 = No Setting)
1
34-04-01
E&M Tie Line Toll Restriction Class
If the system uses Toll Restriction, enter a Toll
Restriction Class (1 ~ 15) for each Tie Line. The
system uses the class you enter in Program
21-05 and 21-06. Make a separate Toll
Restriction Class entry for each night service
mode. You cannot use Program 20-06 to assign
Toll Restriction to Tie Lines.
1 ~ 15
2
Содержание Univerge SV9100
Страница 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Страница 64: ...64 Required Component s None ...
Страница 238: ...238 Walking Code Restriction 663 ...
Страница 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Страница 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Страница 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Страница 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Страница 407: ...407 ICM Distinctive Ringing Flow Chart ...
Страница 442: ...442 CCIS Standard Calls ...
Страница 447: ...447 CCIS VE Standard Calls ...
Страница 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Страница 461: ...461 CCIS VE 911 Calls ...
Страница 519: ...519 3 Dial Relay Number 0 8 0 is for the relay on the GCD CP10 1 8 are relays on the PGD 2 U10 ADP ...
Страница 637: ...637 Cascade Message Notification Flow Chart 1 ...
Страница 638: ...638 Cascade Message Notification Flow Chart 2 ...
Страница 639: ...639 Cascade Message Notification Flow Chart 3 ...
Страница 655: ...655 Cascade Message Flow Chart 1 ...
Страница 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Страница 813: ...813 ...
Страница 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Страница 915: ...915 Communications Interface feature for more ...
Страница 916: ...916 ...
Страница 917: ...917 Operation None ...
Страница 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Страница 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Страница 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Страница 1030: ...1030 Multiline Room Monitoring ...
Страница 1031: ...1031 Single Line Telephone Room Monitoring ...
Страница 1145: ...1145 SMDR flowcharts are located on the following pages SMDR with a GCD CP10 Connection Ethernet ...
Страница 1146: ...1146 SMDR Flowchart Continued ...
Страница 1147: ...1147 SMDR Flowchart Continued ...
Страница 1148: ...1148 SMDR Flowchart Continued Operation Once installed and programmed SMDR operation is automatic ...
Страница 1195: ...1195 System Caller Log Example 2 4 LED Operation On Red Other Using On Green Using Off Not Using ...
Страница 1216: ...1216 To cancel Automatic Headset repeat these steps 4 Press the Headset key Program 15 07 or SC 851 05 to go off hook ...
Страница 1371: ...1371 ...
Страница 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Страница 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...