1045
Security
Description
This system supports the following built-in simple security features:
Warning Message (Watch Mode)
Automatically and periodically send the Watching (VRS) Message from built-In Speaker on
Multiline Terminal or external paging adapter during nightmode.
Enable to accommodate with 3rd Party PIR (Passive Infrared Sensor) or Emergency Button to
provide security feature such as Auto-Emergency Call with Warning (VRS) Message sending.
Remote Inspection
Automatically ring the terminal with preprogrammed schedule in order to check whether users
answer or not. If not answered, Emergency Call is placed to predefined destination automatically.
Conditions
Warning Message (Watch Mode)
Watch mode can provide
Watching message
in a preprogrammed interval via internal
paging group terminals during defined schedule such as night time.
When connected to the system the security sensor will receive sensor detections and send
a prepared warning message or emergency call to a preprogrammed destination.
When connecting security sensor, set Program 20-46-01 Sensor mode to
1
(On), the
security sensor can be connected to the detector circuit on the 2PGDAD. A maximum of
eight sensors can be connected.
Applied voltage when sensor is Off: 5V
Loop current when sensor is On: 14mA
When the system receives a detection signal from a contact on the 2PGDAD detector
circuit. The input circuit contact setting in Program 20-46-12 must match the circuit setting
in Program 10-41-01.
Watch mode can be started and stopped automatically using settings in Program 20-47-01.
Watch mode can be started and stopped manually using Service code (Program 11-12-63) or
function key (SC852:
*
32) assignment. After 10 seconds a warning message is provided,
press again to stop the message.
Security sensor can be started and stopped automatically using settings in
Program 20-48-01.
Security sensor can start and stop manually using Service code (Program 11-12-64) or
function key (SC852:
*
33). Function key (
*
33) blinks until the timer in Program 20-55-01
expires, then the function key turns red. The system can detect a signal from the sensor.
The Watching Message:
Is displayed after the timer in Program 20-44-04 expires.
Can be edited using the Service Code in Program 11-10-20.
Can be recorded up to a maximum of two minutes.
The Length of the watch message depends on the length of the recorded VRS message.
Содержание Univerge SV9100
Страница 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Страница 64: ...64 Required Component s None ...
Страница 238: ...238 Walking Code Restriction 663 ...
Страница 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Страница 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Страница 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Страница 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Страница 407: ...407 ICM Distinctive Ringing Flow Chart ...
Страница 442: ...442 CCIS Standard Calls ...
Страница 447: ...447 CCIS VE Standard Calls ...
Страница 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Страница 461: ...461 CCIS VE 911 Calls ...
Страница 519: ...519 3 Dial Relay Number 0 8 0 is for the relay on the GCD CP10 1 8 are relays on the PGD 2 U10 ADP ...
Страница 637: ...637 Cascade Message Notification Flow Chart 1 ...
Страница 638: ...638 Cascade Message Notification Flow Chart 2 ...
Страница 639: ...639 Cascade Message Notification Flow Chart 3 ...
Страница 655: ...655 Cascade Message Flow Chart 1 ...
Страница 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Страница 813: ...813 ...
Страница 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Страница 915: ...915 Communications Interface feature for more ...
Страница 916: ...916 ...
Страница 917: ...917 Operation None ...
Страница 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Страница 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Страница 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Страница 1030: ...1030 Multiline Room Monitoring ...
Страница 1031: ...1031 Single Line Telephone Room Monitoring ...
Страница 1145: ...1145 SMDR flowcharts are located on the following pages SMDR with a GCD CP10 Connection Ethernet ...
Страница 1146: ...1146 SMDR Flowchart Continued ...
Страница 1147: ...1147 SMDR Flowchart Continued ...
Страница 1148: ...1148 SMDR Flowchart Continued Operation Once installed and programmed SMDR operation is automatic ...
Страница 1195: ...1195 System Caller Log Example 2 4 LED Operation On Red Other Using On Green Using Off Not Using ...
Страница 1216: ...1216 To cancel Automatic Headset repeat these steps 4 Press the Headset key Program 15 07 or SC 851 05 to go off hook ...
Страница 1371: ...1371 ...
Страница 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Страница 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...