1021
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-08-01
Class of Service Options (Outgoing Call
Service)
– Intercom Calls
Turn Off or On Intercom calling for the
extension.
0 = Off
1 = On
COS 1 ~ 15 = 1
20-08-09
Class of Service Options (Outgoing Call
Service)
– Hotline/Extension Ringdown
Turn Off or On Hotline (Ringdown). If disabled
in Class of Service, the settings in Program
21-11 below have no effect.
0 = Off
1 = On
COS 1 ~ 15 = 0
21-01-09
System Options for Outgoing Calls
–
Ringdown Extension Timer (Hotline Start)
After the user lifts the handset, the extension
automatically calls the ringdown destination
after this time. A setting of 0 immediately rings
the programmed extension. Any other setting
delays the ringdown the number of seconds
programmed.
0 ~ 64800 seconds
5
21-11-01
Extension Ringdown (Hotline) Assignment
Program the ringdown (Hotline) source and
destination (target) number, up to 24 digits (960
Hotline assignments). Remember to include the
trunk access code (usually 9) in front of the
number when dialing outside numbers. When
programming Speed Dial
– System numbers as
the destination, the entry should be
#
2 + bin
number (the service code for Speed Dialing and
the Speed Dial bin number).
Maximum of 24 digits
0 ~ 9, *,
#
, Pause, Hook Flash,
@ (Code to wait for answer
supervision)
No Setting
Operation
To place a call if your extension has ringdown programmed:
1.
Lift the handset.
If you want to place a trunk call, press a line key before lifting the handset.
Depending on the setting of your ringdown timer, you may be able to dial an Intercom call before your
ringdown goes through.
If the destination has Handsfree Answerback enabled, your call voice announces. If the destination
has Forced Intercom Ringing enabled, your call rings.
To answer a call if you are another extension ringdown destination:
1.
Speak toward the telephone to answer the incoming voice announcement.
- OR -
Lift the handset or press
Speaker
to answer ringing Intercom call.
Содержание Univerge SV9100
Страница 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Страница 64: ...64 Required Component s None ...
Страница 238: ...238 Walking Code Restriction 663 ...
Страница 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Страница 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Страница 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Страница 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Страница 407: ...407 ICM Distinctive Ringing Flow Chart ...
Страница 442: ...442 CCIS Standard Calls ...
Страница 447: ...447 CCIS VE Standard Calls ...
Страница 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Страница 461: ...461 CCIS VE 911 Calls ...
Страница 519: ...519 3 Dial Relay Number 0 8 0 is for the relay on the GCD CP10 1 8 are relays on the PGD 2 U10 ADP ...
Страница 637: ...637 Cascade Message Notification Flow Chart 1 ...
Страница 638: ...638 Cascade Message Notification Flow Chart 2 ...
Страница 639: ...639 Cascade Message Notification Flow Chart 3 ...
Страница 655: ...655 Cascade Message Flow Chart 1 ...
Страница 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Страница 813: ...813 ...
Страница 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Страница 915: ...915 Communications Interface feature for more ...
Страница 916: ...916 ...
Страница 917: ...917 Operation None ...
Страница 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Страница 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Страница 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Страница 1030: ...1030 Multiline Room Monitoring ...
Страница 1031: ...1031 Single Line Telephone Room Monitoring ...
Страница 1145: ...1145 SMDR flowcharts are located on the following pages SMDR with a GCD CP10 Connection Ethernet ...
Страница 1146: ...1146 SMDR Flowchart Continued ...
Страница 1147: ...1147 SMDR Flowchart Continued ...
Страница 1148: ...1148 SMDR Flowchart Continued Operation Once installed and programmed SMDR operation is automatic ...
Страница 1195: ...1195 System Caller Log Example 2 4 LED Operation On Red Other Using On Green Using Off Not Using ...
Страница 1216: ...1216 To cancel Automatic Headset repeat these steps 4 Press the Headset key Program 15 07 or SC 851 05 to go off hook ...
Страница 1371: ...1371 ...
Страница 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Страница 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...