Calling Party Number Presentation for either ISDN
–
BRI or PRI:
Program
Number
Program Name/Description
Input Data
Default
10-03-05
ETU Setup (PRTA PKG Setup)
– CLIP
Information
Based on this setting, the system includes
Presentation Allowed (1) or Presentation
Restricted (0) in the Setup message to allow or
deny the Calling Party Number. Program
15-01-04 must also be set to 1 if this option is
enabled.
0 = Disable
1 = Enable
1
15-01-04
Basic Extension Data Setup
– ISDN Caller ID
If Program 15-01-04 and Program 10-03-05 are
enabled, the system includes Caller ID in the
Setup message as Presentation Allowed. If
these options are disabled, it is Presentation
Restricted.
0 = Disable
1 = Enable
1
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-08-13
Class of Service Options (Outgoing Call
Service)
– ISDN CLIP
Determine if the ISDN calling line identity
presentation and screening indicators should
be allowed.
0 = Off
1 = On
0
21-12-01
ISDN Calling Party Number Setup for Trunks
Assign Calling Party Numbers for each trunk
(maximum 16 digits per entry). When a call is
made by an extension which does not have an
Extension Calling Number assigned (Program
21-13), the system sends the calling number for
the ISDN trunk defined in 21-12. If the Calling
Party Number is assigned in both Program
21-12 and Program 21-13, the system sends
the data in Program 21-13.
Maximum of 16 characters
(1 ~ 0, *,
#
)
No Setting
21-13-01
ISDN Calling Party Number Setup for
Extensions
Assign a Calling Party Number (maximum 16
digits per entry) to each extension. The calling
number is the subscriber number of the dial-in
number. When a call is made by an extension
which does not have an Extension Calling
Number assigned (Program 21-12), the system
sends the calling number for the ISDN trunk
defined in Program 21-13. If a Calling Party
Number is assigned in both Program 21-12 and
Program 21-13, the system sends the data in
Program 21-13.
Maximum of 16 characters
(0 ~ 9, *,
#
)
No Setting
Содержание Univerge SV9100
Страница 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Страница 64: ...64 Required Component s None ...
Страница 238: ...238 Walking Code Restriction 663 ...
Страница 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Страница 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Страница 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Страница 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Страница 407: ...407 ICM Distinctive Ringing Flow Chart ...
Страница 442: ...442 CCIS Standard Calls ...
Страница 447: ...447 CCIS VE Standard Calls ...
Страница 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Страница 461: ...461 CCIS VE 911 Calls ...
Страница 519: ...519 3 Dial Relay Number 0 8 0 is for the relay on the GCD CP10 1 8 are relays on the PGD 2 U10 ADP ...
Страница 637: ...637 Cascade Message Notification Flow Chart 1 ...
Страница 638: ...638 Cascade Message Notification Flow Chart 2 ...
Страница 639: ...639 Cascade Message Notification Flow Chart 3 ...
Страница 655: ...655 Cascade Message Flow Chart 1 ...
Страница 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Страница 813: ...813 ...
Страница 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Страница 915: ...915 Communications Interface feature for more ...
Страница 916: ...916 ...
Страница 917: ...917 Operation None ...
Страница 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Страница 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Страница 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Страница 1030: ...1030 Multiline Room Monitoring ...
Страница 1031: ...1031 Single Line Telephone Room Monitoring ...
Страница 1145: ...1145 SMDR flowcharts are located on the following pages SMDR with a GCD CP10 Connection Ethernet ...
Страница 1146: ...1146 SMDR Flowchart Continued ...
Страница 1147: ...1147 SMDR Flowchart Continued ...
Страница 1148: ...1148 SMDR Flowchart Continued Operation Once installed and programmed SMDR operation is automatic ...
Страница 1195: ...1195 System Caller Log Example 2 4 LED Operation On Red Other Using On Green Using Off Not Using ...
Страница 1216: ...1216 To cancel Automatic Headset repeat these steps 4 Press the Headset key Program 15 07 or SC 851 05 to go off hook ...
Страница 1371: ...1371 ...
Страница 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Страница 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...