1239
Program
Number
Program Name/Description
Input Data
Default
14-07-01
Trunk Access Map Setup
– Trunk Port
Number
Access Map programming may limit Trunk
Group Routing options.
0 = No access
1 = Outgoing access only
2 = Incoming access only
3 = Access only when trunk on
Hold
4 = Outgoing access and access
when trunk on Hold
5 = Incoming access and access
when trunk on Hold
6 = Incoming and Outgoing
access
7 = Incoming access, outgoing
access and access when trunk
on Hold
Trunk Access Maps: 1 ~ 400
Access Maps
1 ~ 400 = Trunk
Ports 1 ~ 400
assigned with
option 7 access
(incoming and
outgoing access
and access
when trunk is on
Hold).
15-06-01
Trunk Access Map for Extensions
Access Map programming may limit Trunk
Group Routing options.
Trunk Access Maps: 1 ~ 400
1
15-07-01
Programmable Function Keys
Assign a function key for Trunk Group Routing
access (code *02 + trunk group
#
).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
21-02-01
Trunk Group Routing for Extensions
Assign the trunk routes to extensions.
Trunk Group Routes: 1 ~ 100
Day/Night Mode: 1 ~ 8
Route Table Number:
0 ~ 100
(0 = No Setting)
1
21-15-01
Individual Trunk Group Routing for
Extensions
Designate the trunk route accessed when a
user dials the Alternate Trunk Route Access
Code assigned in Program 11-09-02. Trunk
Group Routing is set up in Program 14-06.
Trunk Group Routes: 1 ~ 100
0 ~ 100
(0 = No Setting)
0
23-03-01
Universal Answer/Auto Answer
Let an extension user automatically answer
trunk calls that ring other extensions. When the
user lifts the handset, they automatically
answer the ringing calls based on Trunk Group
Routing programming (defined in Program
14-06).
Day/Night Mode
1 ~ 8
Route Table Number
0 ~ 100
0
25-10-01
Trunk Group Routing for DISA
Assign the Trunk Group Route chosen when a
user places a DISA call into the system and
dials 9. The Trunk Group Routing is defined in
Program 14-06. If the system has ARS, dialing
9 accesses ARS. The route chosen is based on
the DISA Class of Service, which is determined
by the password the caller dials.
Trunk Group Routes: 1 ~ 100
Day/Night Mode = 1 ~ 8
Route Table Number = 0 ~ 100
(0 = No Setting)
1
Содержание Univerge SV9100
Страница 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Страница 64: ...64 Required Component s None ...
Страница 238: ...238 Walking Code Restriction 663 ...
Страница 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Страница 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Страница 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Страница 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Страница 407: ...407 ICM Distinctive Ringing Flow Chart ...
Страница 442: ...442 CCIS Standard Calls ...
Страница 447: ...447 CCIS VE Standard Calls ...
Страница 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Страница 461: ...461 CCIS VE 911 Calls ...
Страница 519: ...519 3 Dial Relay Number 0 8 0 is for the relay on the GCD CP10 1 8 are relays on the PGD 2 U10 ADP ...
Страница 637: ...637 Cascade Message Notification Flow Chart 1 ...
Страница 638: ...638 Cascade Message Notification Flow Chart 2 ...
Страница 639: ...639 Cascade Message Notification Flow Chart 3 ...
Страница 655: ...655 Cascade Message Flow Chart 1 ...
Страница 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Страница 813: ...813 ...
Страница 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Страница 915: ...915 Communications Interface feature for more ...
Страница 916: ...916 ...
Страница 917: ...917 Operation None ...
Страница 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Страница 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Страница 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Страница 1030: ...1030 Multiline Room Monitoring ...
Страница 1031: ...1031 Single Line Telephone Room Monitoring ...
Страница 1145: ...1145 SMDR flowcharts are located on the following pages SMDR with a GCD CP10 Connection Ethernet ...
Страница 1146: ...1146 SMDR Flowchart Continued ...
Страница 1147: ...1147 SMDR Flowchart Continued ...
Страница 1148: ...1148 SMDR Flowchart Continued Operation Once installed and programmed SMDR operation is automatic ...
Страница 1195: ...1195 System Caller Log Example 2 4 LED Operation On Red Other Using On Green Using Off Not Using ...
Страница 1216: ...1216 To cancel Automatic Headset repeat these steps 4 Press the Headset key Program 15 07 or SC 851 05 to go off hook ...
Страница 1371: ...1371 ...
Страница 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Страница 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...