83
Program
Number
Program Name/Description
Input Data
Default
26-03-01
ARS Dial Treatments
– Treatment Code
Assign the Dial Treatments (1 ~ 15) for
automatic ARS dialing translation. Assign Dial
Treatments to Service Numbers (Trunk Groups)
in Program 26-02. The ARS Dial Treatment
options are:
3
- Delete the NPA if dialed as part of the initial
call. This requires at least eight digits in the
ARS table (Program 26-02-01).
2
- Delete the leading digit if dialed as part of
the initial call. This requires at least eight digits
in the ARS table (Program 26-02-01).
1
- Add a leading 1 if not dialed as part of the
initial call. This requires at least eight digits in
the ARS table (Program 26-02-01).
INPA
- Insert the NPA specified by NPA.
DNN
- Outdial the NN number of digits or
execute the code that follows. For example,
D041234 out-dials 124. Valid entries are 0 ~ 9,
#
, *, Wnn (wait nn seconds) and P (pause).
Each digits code counts as a digit. So for
example, if a P was added for a pause, the
entry would look like: D05P1234. This Dial
Treatment can only be added from telephone
programming.
Wnn
- Wait nn seconds.
P
- Pause in analog trunk.
R
- Redial the initially dialed number, including
any modifications.
E
- End of Dial Treatment. All Dial Treatments
must end with the E code.
X
- When ARS is enabled, X must be entered in
the Dial Treatment for the system to output the
extension number of the call originator to the
black box for the E911 feature.
Maximum of 24 characters
No Setting
26-04-01
ARS Class of Service
Set an extension ARS Class of Service
(0 ~ 16). Automatic Route Selection (ARS) uses
ARS Class of Service when determining how to
route extension calls.
Day/Night Mode: 1 ~ 8
Class = 0 ~ 16
0
26-13-01
ARS Class of Service for NetLink (DT800/
DT700)
Use to set an
extension’s ARS Class of Service
when used for NetLink. Automatic Route
Selection uses ARS Class of Service when
determining how to route an
extension’s calls.
Day/Night Mode: 1 ~ 8
Class = 0 ~ 16
0
44-05-01
ARS/F-Route Table
– Trunk Group Number
Select the trunk group number to be used for
the outgoing ARS call.
0 ~ 100, 255
0 = No Setting
255 = Extension Call
0
Содержание Univerge SV9100
Страница 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Страница 64: ...64 Required Component s None ...
Страница 238: ...238 Walking Code Restriction 663 ...
Страница 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Страница 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Страница 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Страница 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Страница 407: ...407 ICM Distinctive Ringing Flow Chart ...
Страница 442: ...442 CCIS Standard Calls ...
Страница 447: ...447 CCIS VE Standard Calls ...
Страница 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Страница 461: ...461 CCIS VE 911 Calls ...
Страница 519: ...519 3 Dial Relay Number 0 8 0 is for the relay on the GCD CP10 1 8 are relays on the PGD 2 U10 ADP ...
Страница 637: ...637 Cascade Message Notification Flow Chart 1 ...
Страница 638: ...638 Cascade Message Notification Flow Chart 2 ...
Страница 639: ...639 Cascade Message Notification Flow Chart 3 ...
Страница 655: ...655 Cascade Message Flow Chart 1 ...
Страница 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Страница 813: ...813 ...
Страница 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Страница 915: ...915 Communications Interface feature for more ...
Страница 916: ...916 ...
Страница 917: ...917 Operation None ...
Страница 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Страница 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Страница 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Страница 1030: ...1030 Multiline Room Monitoring ...
Страница 1031: ...1031 Single Line Telephone Room Monitoring ...
Страница 1145: ...1145 SMDR flowcharts are located on the following pages SMDR with a GCD CP10 Connection Ethernet ...
Страница 1146: ...1146 SMDR Flowchart Continued ...
Страница 1147: ...1147 SMDR Flowchart Continued ...
Страница 1148: ...1148 SMDR Flowchart Continued Operation Once installed and programmed SMDR operation is automatic ...
Страница 1195: ...1195 System Caller Log Example 2 4 LED Operation On Red Other Using On Green Using Off Not Using ...
Страница 1216: ...1216 To cancel Automatic Headset repeat these steps 4 Press the Headset key Program 15 07 or SC 851 05 to go off hook ...
Страница 1371: ...1371 ...
Страница 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Страница 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...