748
Guide to Feature Programming
The items highlighted in gray are read only and cannot be changed.
Program
Number
Program Name/Description
Input Data
Default
10-03-01
ETU Setup (GPZ-IPLE Pkg)
– Trunk Logical
Port Number
Displays the port number assigned to the
GPZ-IPLE.
0 ~ 200
0
10-03-02
ETU Setup (GPZ-IPLE Pkg)
– Trunk Type
Define if the IP Trunks are H.323 or SIP.
0 = H.323
1 = SIP
1
10-12-03
GCD-CP10 Network Setup
– Default
Gateway
Assign the default gateway IP address for the
GCD-CP10.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.254.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
10-12-09
GCD-CP10 Network Setup
– IP Address
Set IP address for GPZ-IPLE.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
172.16.0.10
10-12-10
GCD-CP10 Network Setup
– Subnet Mask
Define the Media Gateway Subnet Mask
Address.
128.0.0.0 | 192.0.0.0 | 224.0.0.0
|240.0.0.0 | 248.0.0.0 | 252.0.0.0
|254.0.0.0 | 255.0.0.0
|255.128.0.0 | 255.192.0.0
|255.224.0.0 | 255.240.0.0
|255.248.0.0 | 255.252.0.0
|255.254.0.0 | 255.255.0.0
|255.255.128.0 | 255.255.192.0
|255.255.224.0 | 255.255.240.0
|255.255.248.0 | 255.255.252.0
|255.255.254.0 | 255.255.255.0
|255.255.255.128
|255.255.255.192
|255.255.255.224
|255.255.255.240
|255.255.255.248
|255.255.255.252
|255.255.255.254
|255.255.255.255
255.255.0.0
10-17-02
H.323 Gatekeeper Setup
– Gatekeeper IP
Address
Define the Gatekeeper IP address for H.323.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
10-17-04
H.323 Gatekeeper Setup
– Preferred
Gatekeeper
When 10-17-01 is set to 1, this is used and sets
the preferred ID of multiple gatekeepers.
Maximum of 124 characters.
No Setting
10-18-01
H.323 Alias Address Setup
– Alias Address
Set the telephone number (Alias Address) to
external gatekeeper.
Dial maximum of 12 digits
(0 ~ 9, *,
#
)
No Setting
10-18-02
H.323 Alias Address Setup
– Alias Address
Type
Set the Alias Address Type to external
gatekeeper.
0 = E164
0
Содержание Univerge SV9100
Страница 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Страница 64: ...64 Required Component s None ...
Страница 238: ...238 Walking Code Restriction 663 ...
Страница 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Страница 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Страница 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Страница 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Страница 407: ...407 ICM Distinctive Ringing Flow Chart ...
Страница 442: ...442 CCIS Standard Calls ...
Страница 447: ...447 CCIS VE Standard Calls ...
Страница 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Страница 461: ...461 CCIS VE 911 Calls ...
Страница 519: ...519 3 Dial Relay Number 0 8 0 is for the relay on the GCD CP10 1 8 are relays on the PGD 2 U10 ADP ...
Страница 637: ...637 Cascade Message Notification Flow Chart 1 ...
Страница 638: ...638 Cascade Message Notification Flow Chart 2 ...
Страница 639: ...639 Cascade Message Notification Flow Chart 3 ...
Страница 655: ...655 Cascade Message Flow Chart 1 ...
Страница 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Страница 813: ...813 ...
Страница 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Страница 915: ...915 Communications Interface feature for more ...
Страница 916: ...916 ...
Страница 917: ...917 Operation None ...
Страница 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Страница 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Страница 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Страница 1030: ...1030 Multiline Room Monitoring ...
Страница 1031: ...1031 Single Line Telephone Room Monitoring ...
Страница 1145: ...1145 SMDR flowcharts are located on the following pages SMDR with a GCD CP10 Connection Ethernet ...
Страница 1146: ...1146 SMDR Flowchart Continued ...
Страница 1147: ...1147 SMDR Flowchart Continued ...
Страница 1148: ...1148 SMDR Flowchart Continued Operation Once installed and programmed SMDR operation is automatic ...
Страница 1195: ...1195 System Caller Log Example 2 4 LED Operation On Red Other Using On Green Using Off Not Using ...
Страница 1216: ...1216 To cancel Automatic Headset repeat these steps 4 Press the Headset key Program 15 07 or SC 851 05 to go off hook ...
Страница 1371: ...1371 ...
Страница 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Страница 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...