CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE
User’s Manual U15260EJ3V1UM
80
7.
Executing EPV command
Select [Device]
→
[Autoprocedure (EPV)].
Figure 5-14. Erase>Program>Verify (EPV) Menu
Toolbar:
When the EPV command is executed, checking the checksum value of the user program, Blank check, Erase,
Program, and Verify
Note
are executed in that order on the
µ
PD70F3025A (if necessary, insert the device to be
newly written in the FA adapter, and execute step 7). In this example, since Read verify after Program is
checked whether the data communication between the PG-FP4 and target device has been correctly
performed after executing the EPV command is checked.
Note
When the Program command is executed, whether the write level is secured is verified after the user
program has been written. Note, however, that this verification does not detect a communication error
of the user program that is transmitted from the PG-FP4 to the target device. For details of this
command, refer to
4.4.3 [Device] menu
.