User’s Manual U15260EJ3V1UM
71
CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE
This chapter explains a series of basic operations of the PG-FP4 with the GUI software, taking a case where the
µ
PD70F3025A is used as the target device as an example. This chapter covers how to start the system, execute the
EPV command, and program the target device.
For the other commands and applications, refer to
CHAPTER 4 PG-FP4 OPERATION USING GUI SOFTWARE
.
•
Series of operations described in this chapter
Here are the operation conditions of this chapter:
HOST interface:
RS-232C interface
Target:
µ
PD70F3025A (with FA adapter)
Communication interface:
SIO H/S 625 kHz
Supply oscillator:
In PG-FP4, 6 MHz, multiplied by 5
Operation mode:
Chip
Supply voltage:
Supplied by PG-FP4
Command options:
Read verify after Program check
(Verification is executed after program command.)
Program download/upload: No check (with user program 1 code only)
1.
Installing GUI software
Install the PG-FP4 GUI software in the PC you are using by referring to
CHAPTER 3 SOFTWARE
INSTALLATION
(if the software has not been installed yet).
2.
Installing parameter file
Copy the parameter file for the
µ
PD70F3025A to the hard disk and install it in <FP4 install path>\PRM.
Download the parameter file from the following:
http://www.necel.com/micro/ods/eng/index.html
3.
Connecting system
<1> Connect the PG-FP4 to the computer with the supplied RS-232C cable.
<2> Select an appropriate AC plug from those supplied with the PG-FP4 (Europe, the UK, the USA and Japan)
and connect it to the AC adapter to configure a PG-FP4 power supply unit.
<3> Connect the PG-FP4 power supply unit to the PG-FP4 and the main power supply.