CHAPTER 4 PG-FP4 OPERATION USING GUI SOFTWARE
User’s Manual U15260EJ3V1UM
65
(c) Advanced setup
Advanced setup is used to specify the programming voltage for programming the target device, command
options, and security flag setting.
When Advanced is clicked, the following window is displayed.
Figure 4-26. Device Setup Window – Advanced
<1> Supply voltage
The supply voltage section allows you to specify the voltage levels for target device programming. Depending
on the target device type, one (V
DD
) or two (V
DD
and V
DD2
) voltage levels need to be specified.
In general, V
DD
/V
DD2
voltages that are supplied when the target device is programmed should be supplied by
the target system. Although they can be supplied by the PG-FP4, the current flow is not large enough to
operate the whole target system (maximum of 200 mA). Therefore, supply voltage via the PG-FP4 only when
a dedicated writing adapter such as an FA adapter is used.