CHAPTER 10 ERROR MESSAGES
User’s Manual U15260EJ3V1UM
107
No.
Message
Error Condition
Possible Workaround
062
Wrb retry exceed
Writeback retries exceed
A device defect is most probably causing this error.
063
Wrb Timeset err
Writeback timeset error
The parameter file may contain invalid data.
Contact NEC Electronics.
070
Write timeout
Write timeout
Communication problem between the PG-FP4 and
the target device. Try the operation again.
071
Write failed
The write operation failed
Either the device was not blank before writing or a
device defect is causing this error.
072
Write retry err
Write retry error
Either the device was not blank before writing or
device defect is causing this error.
073
Wrt. Timeset err
Write timeset error
The parameter file may contain invalid data.
Contact NEC Electronics.
080
Vrf Timeout
Verify timeout
Communication problem between PG-FP4 and the
target device. Try the operation again.
081
Verify failed
Verify failed
The data in the target device’s flash memory is not
the same as in the PG-FP4.
090
IVrf Timeout
Internal verify timeout
Communication problem between the PG-FP4 and
the target device. Try the operation again.
091
IVerify failed
Internal verify error
An error has occurred while the write data level is
checked.
Erase and write the device again.
092
VGT Comm err
Device communication error
Communication problem between the PG-FP4 and
the target device. Try the operation again.
093
SUM Comm err
Device communication error
Communication problem between the PG-FP4 and
the target device. Try the operation again.
094
SCF Comm err
Device communication error
Communication problem between the PG-FP4 and
the target device. Try the operation again.
095
EXR Comm err
Device communication error
Communication problem between the PG-FP4 and
the target device. Try the operation again.
096
EXW Comm err
Device communication error
Communication problem between the PG-FP4 and
the target device. Try the operation again.