CHAPTER 4 PG-FP4 OPERATION USING GUI SOFTWARE
User’s Manual U15260EJ3V1UM
61
<2> Communication interface to device
“Communication interface to device” selects the channel for communication between the PG-FP4 and target
device. For the communication port and communication rate that can be selected, refer to the user’s manual
of the device used.
Figure 4-23. Setup Window – Communication Interface to Device
[Port list box]
Select the mode of communication between the PG-FP4 and target device from the following.
The communication mode is determined by the number of V
PP
or FLMD0
Note
pulses output by the PG-FP4.
The selectable communication mode differs depending on the target device. Refer to the user’s manual of
the target device used and select a mode. With some devices, the number starts from ch1. In this case, ch0
of the parameter on the screen equals ch1 of the device, and the displayed channel number must be shifted
accordingly.
Note
When using a single-power-supply flash memory microcontroller.
Item on Screen
Description
SIO-ch0
SIO (3-wire clocked communication port) channel 0
SIO-ch1
SIO (3-wire clocked communication port) channel 1
SIO-ch2
SIO (3-wire clocked communication port) channel 2
SIO-H/S
SIO (3-wire clocked communication port, with handshake)
IIC-ch0
I
2
C channel 0
IIC-ch1
I
2
C channel 1
IIC-ch2
I
2
C channel 2
IIC-ch3
I
2
C channel 3
UART-ch0
UART (asynchronous communication port) channel 0
UART-ch1
UART (asynchronous communication port) channel 1
UART-ch2
UART (asynchronous communication port) channel 2
UART-ch3
UART (asynchronous communication port) channel 3
Port-ch0
Port (pseudo 3-wire) A
Port-ch1
Port (pseudo 3-wire) B
Port-ch2
Port (pseudo 3-wire) C