D-39
4-2.
ADJUSTMENT OF JUMPER SWITCHES ON NCU BOARD
• Make the correct settings of the jumper switches at six places on the NCU Board accord-
ing to the applicable marketing area.
• When the NCU Board has been replaced, check that the jumper switches are set as
shown below.
✽
Country Classification Jumper Switch Setting
Type
Jumper Switch
Setting
Country
STD
(UL)/
(Others)
STD (UL): Canada, South America, Taiwan, U.S A.
STD (Others): Bahrain, Baltic, Croatia, Hong Kong,
Iran, Kuwait, Malaysia, New Zealand, Poland,
Qatar, Romania, Russia, Singapore, Slovakia, Slov-
enia, Ukraine, Others.
JP2
1 - 2
JP3
1 - 2
JP4
1 - 2
JP5
1 - 2
JP6
1 - 2
TBR-21
Austria, Belgium, Cyprus, Czech, Denmark, Finland,
France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Liechtenstein, Luxembourg,
Netherlands, Norway, Sweden, Switzerland, U.K,.
JP2
2 - 3
JP3
2 - 3
JP4
2 - 3
JP5
2 - 3
JP6
2 - 3
China
China
JP2
only 1
JP3
1 - 2
JP4
1 - 2
JP5
1 - 2
JP6
2 - 3
3
1
2
1
2
3
Setting: 1 - 2
Setting: 2 - 3