S-121
(14) SOFT SWITCH: #14
• Bit 6: If set to 1, machine will become manual RX mode if available memory size less
than 128 K (manual RX mode: Press “Speaker” key and “Start” key, then machine
can start receiving).
(15) SOFT SWITCH: #15
Bit
No.
Designation
Function
Initial
Setting
Bit HEX
8
Reserved Reserved
0
0
7
Reserved Reserved
0
6
Memory size level
To RX
1: Up to 128 KB
0: Based on system configuration
0
5
Reserved Reserved
0
4
Reserved Reserved
0
2
3
Time between
V.34 ANSam sig-
nal and FSK DIS
signal
0
2
1
1
0
Bit
No.
Designation
Function
Initial
Setting
Bit HEX
8
Reserved Reserved
0
0
7
Reserved Reserved
0
6
Reserved Reserved
0
5
Reserved Reserved
0
4
Reserved Reserved
0
1
3
Reserved Reserved
0
2
Reserved Reserved
0
1
Remote side no
document to be
polled
0: Not to generate error report document to be
polled
1: Generate error report after communication
end
1
Timer
50
ms
60
ms
70
ms
80
ms
100
ms
120
ms
140
ms
160
ms
Bit 3
0
0
0
0
1
1
1
1
Bit 2
0
0
1
1
0
0
1
1
Bit 1
0
1
0
1
0
1
0
1
Содержание NEFAX 671