S-163
19
Recording length
capability
20
21
22
23
24 Extension field
“0”= Without
“1”= With
25 Reserved
26
“0”= Invalid
“1”= Un-compressed mode
27
“0”= Invalid
“1”= ECM
28 Set to “0”
Frame size 0: 256 octets
Frame size 1: 64 octets
29 Set to “0”
30 Set to “0”
31
“0”= Invalid
“1”= T.6 coding capability
“0”= Invalid
“1”= T.6 coding enabled
32 Extend field
“0”= Without
“1”= With
33
“0”= Invalid
“1”= Field not valid capability
34
“0”= Invalid
“1”= Multiple selective polling capability
Set to “0”
Bit
No.
Designation
DIS/ DTC
DCS
Bit No. Recording length capa-
bility
20 19
0 0 A4 (297 mm)
0 1
A4 (297 mm) and B4
(364 mm)
1 0 Unlimited
1 1 Invalid
Bit No.
Recording length
capability
20 19
0 0 A4 (297 mm)
0 1 B4 (364 mm)
1 0 Unlimited
1 1 Invalid
Bit No.
Minimum scan line time
capability at the receive
23 22 21
0 0 0
20 ms at 3.85 1/mm: T 7.7 = T 3.85
20 ms
0 0 1 5 ms at 3.85 1/mm: T 7.7 = T 3.85
0 1 0
10 ms at 3.85 1/mm: T 7.7 = T 3.85
10 ms
0 1 1
20 ms at 3.85 1/mm: T 7.7 = 1/2 T
3.85
1 0 0
40 ms at 3.85 1/mm: T 7.7 = T 3.85
40 ms
1 0 1
40 ms at 3.85 1/mm: T 7.7 = 1/2 T
3.85
1 1 0
10 ms at 3.85 1/mm: T 7.7 = 1/2 T
3.85
1 1 1 0 ms at 3.85 1/mm: T 7.7 = T 3.85
Bit No. Minimum scan line
time
23 22 21
0 0 0 20 ms
0 0 1 5 ms
0 1 0 10 ms
1 0 0 40 ms
1 1 1 0 ms