T-23
(11) C13F0: Laser error
<Detection Timing>
<Troubleshooting Procedures>
(12) C1468: EEPROM error
<Detection Timing>
<Troubleshooting Procedures>
Description
• The laser output exceeds the upper limit value.
• The laser output remains lower than the lower limit value.
Relevant Electric Parts
PH Unit
Flat cable
Controller/Mechanical Control Board (PWB-P)
Step
Action
Ref. Page
WIRING DIAGRAM
Control Signal
Location
(Electric Parts)
1
Check cables for connection and
correct as necessary.
–
–
–
2
Replace PH Unit.
☞
D-19
–
–
3
Replace PWB-P.
☞
D-12
–
–
Description
• An EEPROM not written with initial data was detected.
Relevant Electric Parts
Controller/Mechanical Control Board (PWB-P)
Step
Action
Ref. Page
WIRING DIAGRAM
Control Signal
Location
(Electric Parts)
1
Unplug, then plug in the power cord, and
turn off this machine, then turn it on
again.
–
–
–
2
Check the connection of the EEPROM
on the PWB-P, and then correct it if nec-
essary.
–
–
–
3
Replace PWB-P.
☞
D-12
–
–
4
Replace EEPROM.
☞
D-50
–
–