S-112
(3)
SOFT SWITCH: #03
• Bit 8: If this bit is set to 1, the answer machine will send the machine name (which is that
set in INITIAL USER DATA of Utility Mode) by NSF frame after connection.
• Bit7: Can input Pause key to insert pause time between digits, this can put more than
one “P” at the end of access telephone number during calling to other parties by
using PBX system.
Bit
No.
Designation
Function
Initial
Setting
Bit HEX
8
Send out NSF
frame with station
ID
1: Yes
0: No
1
8
7
Number of pause
within phone num-
ber
0: No limitation
1: Max. up to 2 “P” within inputted telephone
number
0
6
Re-dial prohibit for
NO ANSWER
0: Continue to dial
1: Not allowed to re-dial if no any FAX signal or
detected busy tone after dialing
0
5
Reserved
Reserved
0
4
RX level setting
0
6
3
1
2
1
1
0
RX level
(dB)
-49 -48 -47 -46 -45 -44
-43
Bit 4
0
0
0
0
0
0
0
Bit 3
0
0
0
0
1
1
1
Bit 2
0
0
1
1
0
0
1
Bit 1
0
1
0
1
0
1
0
RX level
(dB)
-42 -41 -40 -39 -38 -37 -36
Bit 4
0
1
1
1
1
1
1
Bit 3
1
0
0
0
0
1
1
Bit 2
1
0
0
1
1
0
0
Bit 1
1
0
1
0
1
0
1
RX level
(dB)
Reserved
Bit 4
1
1
Bit 3
1
1
Bit 2
1
1
Bit 1
0
1