S-119
(11) SOFT SWITCH: #11
• Bit 6: If this bit is set to 1, not allowed user to select Pulse dial, and this function open for
serviceman to change.
• Bit 7: Bit set to 1, LCD will show the command between each party.
(12) SOFT SWITCH: #12
• Bit 1- 2: Delay time from FSK mode to PSK mode, this is used for G3 mode only, V.34
does not need this setting.
• Bit 6-7: If level reads “1”, machine. Will go down to next lower speed for next data phase.
Bit
No.
Designation
Function
Initial
Setting
Bit
HEX
8
Reserved Reserved
0
0
7
Detect dial tone
after pre-fix num-
ber
0: No
1: Yes
0
6
Pulse dial allowed
to select
0: Yes
1: Not allowed
0
5
Protocol signal
display mode
0: Not to display
1: Display V8 or T30 command within communica-
tion.
0
4
Reserved Reserved
0
0
3
Reserved Reserved
0
2
Reserved Reserved
0
1
DTMF high fre-
quency dB value
0: Base on SW19 (1-4)
1: High 1dB
0
Bit
No.
Designation
Function
Initial
Setting
Bit HEX
8
ECM mode capa-
bility
1: Yes
0: No - also disable V.34 modem capability
1
8
7
V.34 fall back
level for V.34 TX.
0
6
0
5
Send CTC after
4th PPR
0: Send CTC (Continue To Correct)
1: Send EOR (End Of Transmission)
0
4
Reserved Reserved
0
0
3
Send EOR after
lowest speed
0: Send DCN (Redial)
1: Send EOR_xxx (Germany PTT)
0
2
TCF transmission
timing after DCS
0
1
0
Counter
1
2
3
4
Bit 7
0
0
1
1
Bit 6
0
1
0
1
Description
70 ms
80 ms 90 ms
100 ms
Bit 2
0
0
1
1
Bit 1
0
1
0
1