S-114
(5)
SOFT SWITCH: #05
Bit
No.
Designation
Function
Initial
Setting
Bit HEX
8
Push button on/off
timing (PB)
0
0
7
0
6
Relation between
dialed No. and No.
of dial pulse
0
5
0
4
Dial pulse make
ratio select (MR)
1
A
3
0
2
1
1
0
Timing
(ms)
ON
100
70
70
90
OFF
140
70
140
90
Bit 8
0
0
1
1
Bit 7
0
1
0
1
# 1
1
2
9
Reserved
# 2
2
3
8
# 3
3
4
7
# 4
4
5
6
# 5
5
6
5
# 6
6
7
4
# 7
7
8
3
# 8
8
9
2
# 9
9
10
1
# 0
10
1
10
Bit 6
0
0
1
1
Bit 5
0
1
0
1
PPS
20 20 20 Rese
rved
16 16 16 Rese
rved
MR(%) 33 40 30
33 40 30
Bit 4
0
0
0
0
0
0
0
0
Bit 3
0
0
0
0
1
1
1
1
Bit 2
0
0
1
1
0
0
1
1
Bit 1
0
1
0
1
0
1
0
1
PPS
10 10
10
10
Reserved
MR(%) 33 40
30
32
Bit 4
1
1
1
1
1
1
1
1
Bit 3
0
0
0
0
1
1
1
1
Bit 2
0
0
1
1
0
0
1
1
Bit 1
0
1
0
1
0
1
0
1
Содержание NEFAX 671