S-70
5-6.
Counter Function
• The following counters can be shown on display.
(1)
Counter
• The counter values can be displayed.
ADF
SUB
ZOOM
TEST
COPY
To adjust for variations in the accu-
racy of ADF and their mounting
accuracy by varying the scanning
zoom ratio in the sub-scanning
direction.
Press the Start key to begin
printing the test page.
ADJUST
• The setting range is 95 (-2.0
%) to 105 (+2.0 %).
• (1 increment = 0.4%)
• The default setting is “
100
”.
ADF
MAIN
REGIST
TEST
COPY
To adjust for variations in the accu-
racy of ADF and their mounting
accuracy by varying the scanning
start position in the main scanning
direction.
Press the Start key to begin
printing the test page.
ADJUST
• The setting range is 90 (-5.0
mm) to 110 (+5.0 mm).
• (1 increment = 0.5 mm)
• The default setting is “
100
”.
ADF
SUB
REGIST
TEST
COPY
To adjust for variations in the accu-
racy of ADF and their mounting
accuracy by varying the scanning
start position in the sub-scanning
direction.
Press the Start key to begin
printing the test page.
ADJUST
• The setting range is 90 (-5.0
mm) to 110 (+5.0 mm).
• (1 increment = 0.5 mm)
• The default setting is “
100
”.
SHAD-
ING
LEVEL
ADJUST
Save the Shading value .When the
shading page is unclean then
machine execute the shading will
get wrong value, in this time can
use the save shading.
• This function is the same with
shading level of the Image
Sensor by using A4 size
white sheet of paper in case
of following condition.
No.
Indication on LCD
1
TOTAL COUNTER
2
PM COUNTER
3
I/C COUNTER
4
APPLICATION COUNTER
5
SCAN COUNTER
Function
Purpose
Setting Details/Precautions