S-146
(49) SOFT SWITCH: #49
(50) SOFT SWITCH: #50
• Bit 8: Can select cancel this job and print out report or start to send in case of time when
memory full condition occurs
Bit
No.
Designation
Function
Initial
Setting
Bit HEX
8
Reserved
Reserved
0
0
7
Reserved
Reserved
0
6
Print RX mailbox
report method
0: Based on RX RESULT REPORT setting
1: Always printing
0
5
Redial method if
communication fail
0: Redial again
1: Based on redial time interval
0
4
No. of rings
0
1
3
0
2
0
1
1
Bit
No.
Designation
Function
Initial
Setting
Bit HEX
8
Transmit or cancel
after time out in
“Memory TX”
0: Cancel and print out
1: Transmission
0
0
7
Reserved Reserved
0
6
Reserved Reserved
0
5
Reserved Reserved
0
4
Reserved Reserved
0
0
3
Reserved Reserved
0
2
Reserved Reserved
0
1
Reserved Reserved
0
No. of rings 1
2
3
4
5
6
7
8
Bit 4
0
0
0
0
0
0
0
0
Bit 3
0
0
0
0
1
1
1
1
Bit 2
0
0
1
1
0
0
1
1
Bit 1
0
1
0
1
0
1
0
1
No. of rings 9
10 11 12 13 14 15 16
Bit 4
1
1
1
1
1
1
1
1
Bit 3
0
0
0
0
1
1
1
1
Bit 2
0
0
1
1
0
0
1
1
Bit 1
0
1
0
1
0
1
0
1