T-47
8-4.
Troubleshooting Functions
Scan to E-Mail Transmission
Internet Fax Transmission
No.
Condition
Cause
Action
1
Transmission is not
possible.
The connections are
incorrect.
Check the LED indicator on the
hub, and check the connections.
The settings necessary
for the device are not reg-
istered.
Specify the necessary network set-
tings.
The LAN cable is dam-
aged.
Replace the LAN cable.
2
Transmission is
possible, but the
image cannot be
outputted at the
recipient’s terminal
or computer.
The recipient’s terminal is
not able to handle the
sent image.
Change the size, resolution and
coding method so that they are sup-
ported by the recipient’s terminal,
and then try sending the data again.
The document text was
not inserted when the
data was sent.
With some e-mail applications, if an
e-mail is received containing no text
and only an attached file, it may not
be possible to open the attached
file. Therefore, text should be
inserted into the document that is
sent.
No.
Condition
Cause
Action
1
Transmission is not
possible.
The connections are
incorrect.
Check the LED indicator on the
hub, and check the connections.
The settings necessary
for the device are not reg-
istered.
Specify the necessary network set-
tings.
The LAN cable is dam-
aged.
Replace the LAN cable.
2
An interruption in
the transmission
was specified, but
the transmission
was not inter-
rupted.
It takes some time to
interrupt an Internet fax
transmission.
Wait until the transmission is inter-
rupted.