S-69
5-5.
Adjust Function
• The following counters can be shown on display.
(1)
Adjust
Precautions for making test copies with functions from the “ADJUST” menu
• The test pattern should be positioned vertically.
• Use paper loaded into Tray1 to make the test copy.
No.
Indication on LCD
1
PRN MAIN REGIST
2
PRN SUB REGIST
3
ADF SUB ZOOM
4
ADF MAIN REGIST
5
ADF SUB REGIST
6
TC TYPE
7
SHADING LEVEL
Function
Purpose
Setting Details/Precautions
PRN
MAIN
REGIST
TEST
COPY
To vary and adjust the print start
position in the main scanning
direction.
• If the image on the copy devi-
ates in the CD direction
• When the PH unit has been
replaced
Press the Start key to begin
printing the test page.
ADJUST
• The setting range is
60 (-40 mm) to 140 (+40
mm).
• (1 increment = 0.1 mm)
• The default setting is “
100
”.
PRN
SUB
REGIST
TEST
COPY
To vary and adjust the print start
position in the sub-scanning direc-
tion.
• If the image on the copy devi-
ates in the FD direction
• When the PH unit has been
replaced
Press the Start key to begin
printing the test page.
ADJUST
• The setting range is
87 (-5.98 mm) to
113 (+5.98 mm).
• (1 increment = 0.46 mm)
• The default setting is “
100
”.
TEST PATTERN 1
4980S530AA