Troubleshooting 8-5
Error
code
Error message
Recommended Action
02D1
System Memory exceeds the CPU's caching
limit.
02F4
EISA CMOS not write able.
02F5
DMA Test Failed.
02F6
Software NMI Failed.
02F7
Fail-safe Timer NMI Failed.
Contact your service representative.
0B22
Processors are installed out of order.
Request the maintenance to replace the
CPU.
0B28
Unsupported CPU detected on CPU socket
1.
0B29
Unsupported CPU detected on CPU socket
2.
Make sure that the server supports the
CPU. If you are not sure, contact your
service representative to request the
maintenance.
0B30
FAN1 Alarm occurred.
0B31
FAN2 Alarm occurred.
0B32
FAN3 Alarm occurred.
0B33
FAN4 Alarm occurred.
0B34
FAN5 Alarm occurred.
0B35
FAN6 Alarm occurred.
0B36
FAN7 Alarm occurred.
0B37
FAN8 Alarm occurred.
Clean the internal cooling fans.
Contact your service representative to
replace the fan.
0B42
Resource Conflict
0B43
Warning: IRQ not configured
0B45
System configuration Data Write Error
Contact your service representative.
0B50
Processor #1 with error taken off line.
0B51
Processor #2 with error taken off line.
0B5F
Forced to use Processor with error
Because an error is detected in every CPU,
the system is forcibly started. Contact your
service representative.
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B64
DIMM group #5 has been disabled
0B65
DIMM group #6 has been disabled
Contact your service representative.
0B70
The error occurred during temperature
sensor reading.
Contact your service representative.
0B71
System Temperature out of the range.
Contact your service representative to
replace the fan.
0B74
The error occurred during voltage sensor
reading.
0B75
System voltage out of the range.
Contact your service representative.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core Hardware failure.
0B83
BMC IBF or OBF check failed.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B8A
BMC SEL area full
Clear the system event logs by using the
BIOS SETUP utility (see Chapter 4).
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
Содержание Express5800/120Rj-2
Страница 16: ...x This page is intentionally left blank ...
Страница 19: ...Notes on Using Your Server 1 3 Internal View ...
Страница 34: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Страница 90: ...3 24 Setting Up Your Server This page is intentionally left blank ...
Страница 129: ...Configuring Your Server 4 39 The detailed settings is continued to the next page Click Next to view more information ...
Страница 140: ...4 50 Configuring Your Server Use this menu to define several physical drives PD as a disk group DG ...
Страница 164: ...4 74 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 172: ...4 82 Configuring Your Server This page is intentionally left blank ...
Страница 215: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 240: ...7 12 Maintenance This page is intentionally left blank ...
Страница 350: ...9 74 Upgrading Your Server Removal Remove the backup device in reverse order of the installation steps ...
Страница 354: ...9 78 Upgrading Your Server This page is intentionally left blank ...
Страница 364: ...C 2 IRQ This page is intentionally left blank ...
Страница 412: ...E 24 Installing Windows Server 2003 This page is intentionally left blank ...
Страница 414: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 418: ...G 4 Product Configuration Record Table This page is intentionally left blank ...