Chapter 4
Analog Input
X Series User Manual
4-36
ni.com
Using a Digital Source
To
u
se AI Start Trigger with a digital so
u
rce, specify a so
u
rce and an edge.
The so
u
rce can be any of the following signals:
•
PFI <0..15>
•
RTSI <0..7>
•
Co
u
nter
n
Internal O
u
tp
u
t
•
PXI_STAR
•
PXIe-DSTAR<A,B>
•
Change Detection Event
•
AO Start Trigger (ao/StartTrigger)
•
DI Start Trigger (di/StartTrigger)
•
DO Start Trigger (do/StartTrigger)
The so
u
rce also can be one of several other internal signals on yo
u
r DAQ
device. Refer to
Device Routing in MAX
in the
NI-DAQmx Help
or the
LabVIEW Help
for more information.
Yo
u
also can specify whether the meas
u
rement acq
u
isition begins on the
rising edge or falling edge of AI Start Trigger.
Using an Analog Source
When yo
u
u
se an analog trigger so
u
rce, the acq
u
isition begins on the
first rising edge of the Analog Comparison Event signal.
Routing AI Start Trigger to an Output Terminal
Yo
u
can ro
u
te AI Start Trigger o
u
t to any PFI <0..15>, RTSI <0..7>, or
PXIe-DSTARC terminal. The o
u
tp
u
t is an active high p
u
lse. All PFI
terminals are config
u
red as inp
u
ts by defa
u
lt.
The device also
u
ses AI Start Trigger to initiate pretriggered DAQ
operations. In most pretriggered applications, a software trigger generates
AI Start Trigger. Refer to the
AI Reference Trigger Signal
section for a
complete description of the
u
se of AI Start Trigger and AI Reference
Trigger in a pretriggered DAQ operation.