Mylex Disk Array Controller Driver for UnixWare
5-8
Disk Array Controller Software Kit User’s Manual
2. Insert a non-bootable DOS-formatted floppy diskette in the diskette
drive and run:
pcipatch.exe a:
↵
Use the diskette you’ve just created when requested in the procedure below.
To install the UnixWare driver for the Mylex Disk Array Controller:
1. Insert the patch diskette in the file server’s diskette drive.
2. Type the following (match case exactly as shown):
pkgadd -d diskette1
↵
3. When asked for the package name, select the appropriate name from
the list and press Enter.
The patch files are installed.
4. Remove the patch diskette, then insert the Software Kit UnixWare
diskette into the floppy diskette drive.
5. Type the following (match case exactly as shown):
pkgadd -d diskette1 dak
↵
The new controller driver is installed.
6. Rebuild the Kernel:
/etc/conf/bin/idbuild -B
↵
7. Reboot the system:
shutdown -i0 -g0 -y
↵