SNMP Installation, Operation & Definition
Manual No. 771929
A-23
A
P
P
E
N
D
I
C
E
S
A
Notes:
• a8ControllerNumber, a8ScsiBusId, and a8CabinetNumber comprise
the Index for the search operation.
• This is a READ-ONLY object. No SET operations are allowed.
• A GET operation returns information about the object at the address
(a8ControllerNumber/a8ScsiBusId/a8ScsiTargetId) specified in the
argument.
• A GETNEXT operation returns information about the next object at the
smallest address greater than the address specified in the argument.
• The lowest address of a device (a8ControllerNumber/a8ScsiBusId/
a8CabinetNumber) is defined as 0/0/0, followed by 0/0/1, .... 0/1/0, 0/1/
1,... 1/0/0,1/0/1 and so on.
• Controller numbers start at 0. Channel numbers start at 0. Target IDs
start at 0.
Table object
Data
Type
Description
a8NumberOfFansFailed
1.3.6.1.4.1.1608.1.1.1.8.1.16
Integer
The number of fans in the
“failed” state
a8NumberOfPowerSupplyUnitsFailed
1.3.6.1.4.1.1608.1.1.1.8.1.17
Integer
The number of power supply
units in the “failed” state
a8NumberOfHeatSensorsFailed
1.3.6.1.4.1.1608.1.1.1.8.1.18
Integer
The number of heat sensors in
the “failed” state
Table A-10. Fault Management Cabinet Information Group
Содержание Disk Array controller Software Kit 2.01
Страница 2: ......
Страница 6: ......
Страница 12: ...xii Disk Array Controller Software Kit User s Manual...
Страница 20: ...Requirements 1 8 Disk Array Controller Software Kit User s Manual...
Страница 84: ...System Administration Utility for Windows NT 4 0 3 36 Disk Array Controller Software Kit User s Manual...
Страница 124: ...Shell Utility for UnixWare 5 20 Disk Array Controller Software Kit User s Manual...
Страница 154: ...Installing TCP IP Windows NT B 4 Disk Array Controller Software Kit User s Manual...
Страница 171: ......