PAGE 34 — DIS185SSI4F AIR COMPRESSOR • OPERATION MANUAL — REV. #0 (12/19/16)
Figure 45. Main Switch (OFF Position)
RESTART
1. Turn the main switch (ignition switch) key to the
ON
position (Figure 46).
Figure 46. Main Switch (RTP Verification)
2. Press the down arrow key (
) to select PSI air
pressure. The
PSI AIR PRESSURE
LED should light
up (
GREEN
).
3. If there is residual pressure remaining inside the tank,
the 7-segment display will indicate "rtp" (residual tank
pressure) as shown in Figure 47. When this message is
displayed, the engine cannot be immediately restarted.
Wait
90 seconds
,
until the pressure reading on the
7-segment display indicates zero, before attempting
to restart.
Figure 47. Residual Tank Pressure
4. Once the remaining tank pressure has discharged and
the 7-segment display reads "
0
", press and hold the
RUN
button on the control panel for at least 2 seconds
to restart the compressor.
MAIN SWITCH
OFF
ON
OFF
OFF
OFF
NOTICE
The residual air pressure inside the compressor tank
must be zero before the engine can be restarted. Wait
at least
90 seconds
before attempting to restart the
engine.
MAIN SWITCH
OFF
ON
OFF
OFF
OFF
SHUTDOWN
1. Place the selected air outlet valve (Figure 43) in the
CLOSED
position to stop the flow of compressed air
to the load.
Figure 43. Air Outlet Valve (CLOSED)
2. Verify that engine speed decreases to no load speed
(approx. 1350 rpm).
3. Run the engine at no load for 3 – 5 minutes until it cools.
4. Press the
STOP
button (Figure 44) on the control panel.
The compressed air remaining in the air compressor
will automatically discharge.
DO NOT
use the air outlet
valves to discharge the remaining air.
Figure 44. STOP Button (Unit Shutdown)
5. Turn the main switch (ignition switch) key to the
OFF
position (Figure 45). Remove key and place in a safe
location.
WARNING
NEVER
discharge the compressed air via the air
outlet valve, as oil may be mixed with the discharged
air. This discharged air (residual pressure) can cause
severe bodily injury. Allow the compressed air to
dissipate completely (approximately 90 seconds) before
removing air hoses from the air outlet valves.
CLOSED
AIR
OUTLET
VALVE
OPE
N
STOP
STOP
OPERATION