Pic #28 Starters without Air Panel
If
you have purchased the
ELECTRIC DRIVE CROSS-OVER™
with the
MCWW OVERDRIVE®
INVERTER BOX,
connect each motor to terminal #2 and terminal #3. Connect the box to a supply of
120-208 VAC/3PH/30 AMPS CIRCUIT ONLY! (See picture #29)
Connect
the
RUN SIGNAL INPUT
(terminal #6) to one function of your car wash controller.
Connect
the retract air panel to one function of your car wash controller and through T
ERMINALS 4, 5.
WARNING
!
THE D/S AND P/S AIR VALVE INTERLOCK CONTACT
HAS TO BE CONNECTED IN SERIES WITH THE OPTIONAL AIR
RETRACT PANEL (SEE PICTURE #29).
IF YOUR CROSSOVER
®
WRAP IS EQUIPPED WITH A DIFFERENT VFD,
VERIFY THAT RETRACT AIR PANEL IS CONNECTED IN SERIES WITH THE
VFD’S FAULT CONTACTS. IN THE EVENT OF A FAULT FROM THE VFD,
THE WRAP HAS TO BE RETRACTED TO AVOID POSSIBLE DAMAGES TO
THE CAR OR THE EQUIPMENT.